Supplied By www.heating spares.co Tel. 0161 620 6677
6.0
Commissioning the Stove – Page 13
6.1 Checking Gas Soundness
1.
Turn on the gas supply and check for gas soundness
with leak detection fluid (to BS 6891).
6.2 Checking Operation of the Stove
1.
Remove the screw from the pressure test point on the
gas tap (adjacent to the control knob) and fit a pressure
gauge (Fig. 20).
2.
Purge the air from the appliance by pushing in the
control knob and rotating to the ignition position (Fig.
21). Allow the air in the pipework to be purged, and
then rotate the knob further to operate the piezo igniter.
The pilot should light.
3.
Once the pilot is established push the control knob in
and turn to the HIGH setting. Check the setting
pressure. (Setting pressure detail found in Section 2.0
Technical Data.)
4.
Turn the control knob to the OFF position, disconnect
the pressure gauge and refit the pressure test point
sealing screw.
6.3 Spillage Monitoring Device
(Fig. 22)
1
The stove incorporates a spillage monitoring device.
This will cut off the gas supply in the event of spillage of
combustion products into the room.
2.
In the event of this occuring there is a reset procedure.
Wait for 10 minutes before trying to reset the stove.
3.
Unscrew the cap off the reset device and press in the
red button with a small screwdriver or similar
instrument.
4.
Relight the stove as previously described. If this is not
possible, wait a further 5 minutes before pressing the
red button. If this fails, wait until the stove is completely
cool and reset it.
5.
If the stove cannot be re-set or the spillage monitoring
device is frequently activated the flue condition must be
investigated.
WARNING: The spillage monitoring device must not be
adjusted in any way. The spillage monitoring device
must not be altered so that it will not operate or be
bypassed in any way. Only use genuine Baxi spare
parts.