3.0 Site Requirements – Page 8
3.5 Gas Supply & Connection
1.
Determine where the gas supply is to be connected to
the appliance. This may be done from either the left or
right side, from the front, or a concealed fitting from the
rear.
Turn off any appliances that are fed by the meter and
isolate the gas supply by turning off at the meter.
2.
The inlet elbow of the stove will accept 8mm OD tubing
(Fig. 5).
3.
A suitable isolating cock and disconnecting union
should be always be fitted in the supply feed to the fire
to facilitate servicing.