page 4

Installation – Page 4

PREPARATION

(a)

Where the closure plate is more than adequate in height to
cover the fireplace opening, trim a minimum of 35mm (1
3/8 in) from the top of the closure plate to prevent the
sealing tape being seen above the fire. Where the closure
plate is inadequate to cover the fireplace opening
completely or where it is required for the sake of
appearance a NON-COMBUSTIBLE infill panel or
surround may be used. The infill panel should be provided
with a rectangular opening at least 508mm (20in) high by
305mm (12in) wide and must be securely fixed and sealed
to the wall to prevent air leakage into the flue.

(b)

Fit the closure plate centrally across the fire opening and
seal all four edges but ensure that the ventilation hole at
the bottom of the closure plate is not covered and that the
floor behind the closure plate does not restrict the
ventilation hole.

(c)

Apply a lighted taper, match or smoke match to the flue
spigot opening in the closure plate before fitting the fire. If
there is a definite flow into the opening in the closure plate,
proceed with the installation. If there is not a definite flow
into the opening, pre-heat the chimney for a few minutes
then re-check for the flue pull. If there is still no definite
flow into the flue spigot opening in the closure plate the
chimney may require attention. DO NOT FIT THE FIRE -
SEEK EXPERT ADVICE.

HEARTH FIXING
Fireplace or Surround

(a)

Fit the fire backing plate to the fire using the M5 x 8mm
thread forming screws provided. The backing plate may be
screwed to the wall for extra support if necessary (Fig. 6).

(b)

Position the fire (minus the outer case) against the closure
plate and determine the position of the gas connection.

(c)

Adjust the feet to level the fire (Fig.7). Check that the fire is
sufficiently stable.

WALL FIXING

(a)

Fit the two wall mounting brackets using the four No. 8 x
3/8in self tapping screws provided (Fig. 7).

(b)

Fit the fire backing plate to the fire using the M5 x 8mm
thread forming screws provided.(Fig. 6)

(c)

Mark the position of the bottom two fixing screws then drill
and plug the wall (Fig. 4).

(d)

Fix two No. 8 x 1 ½in screws into the wall leaving 3 - 4mm
(1/8 in - 5/32 in) clearance under the screw head then
locate the fire onto the screws.

(e)

Push the fire backwards until the fire backing plate touches
the surround or finished wall face. Mark the position of the
two lower securing holes in the fire backing plate (Fig. 6).

(f)

Remove the fire then drill and plug the wall.

(g)

Replace the fire then screw the fire back to the wall and
tighten all four screws.

CONNECTING THE GAS SUPPLY

Rc ¼ (¼in BSP internal taper).

NOTE: If a hole has to be cut in the closure plate for the gas
supply pipe, seal the opening between the gas pipe and the
closure plate, ensuring that the ventilation hole is kept
clear.

(a)

Make the gas connection to the union elbow.

(b)

Fit the control knob and make sure that the tap is off. (Turn
fully clockwise).

(c)

Turn the gas on, check for gas soundness.

Summary of Contents for EBONY SUPER

Page 1: ...heating spares co Tel 0161 620 6677 Page 1 Please leave these Instructions with the User Baxi Ebony Super Gas Fire Comp No 236202 Issue 4 10 99 Installation and Servicing Instructions Baxi Ebony Super G C No 32 077 37 ...

Page 2: ...ndling these articles to ensure the release of dust or fibres is kept to a minimum To ensure that the release of fibres from these articles is kept to a minimum during installation and servicing it is recommended that a H E P A filtered vacuum is used to remove any dust soot or other debris accumulated in and around the appliance This should be performed before and after working on the installatio...

Page 3: ...CAL CONNECTION THIS APPLIANCE MUST BE EARTHED ALL EXTERNAL WIRING BETWEEN THE APPLIANCE AND THE ELECTRICAL SUPPLY SHALL COMPLY WITH CURRENT I E E REGULATIONS The mains lead has the following specifications 16 0 2mm 3 core PVC covered PVC insulated wire to BS 6500 IMPORTANT Mains lead wires Green and yellow Earth Blue Neutral Brown Live FOR THE MAINS PLUG USE A 3AMP FUSE The appliance is supplied w...

Page 4: ...attention DO NOT FIT THE FIRE SEEK EXPERT ADVICE HEARTH FIXING Fireplace or Surround a Fit the fire backing plate to the fire using the M5 x 8mm thread forming screws provided The backing plate may be screwed to the wall for extra support if necessary Fig 6 b Position the fire minus the outer case against the closure plate and determine the position of the gas connection c Adjust the feet to level...

Page 5: ... position and wait for 3 minutes before attempting to light the pilot again d Push in the control knob and turn fully anti clockwise Check that the ignition is satisfactory e Check the fire pressure with the control knob turned fully anti clockwise The pressure should be 14 1mbar 1 0mbar 5 6 in wg 0 4 in wg No adjustment is provided on the fire Turn the control knob to the OFF position Remove the ...

Page 6: ...ve the outer case for access to all controls a Pull off the control knob b Remove the cover panel under the front of the fire by grasping it firmly by its side edges and pulling forwards c Remove the two case securing screws Fig 7 d Lift the case away from the heat exchanger 2 Remove the glass front panel Fig 10 a Ensure that the glass front panel is cold b Slide the glass front panel retaining cl...

Page 7: ...Supplied By www heating spares co Tel 0161 620 6677 Ebony Super Baxi Heating Ltd page 7 Fit the Outer Case Page 7 ...

Page 8: ...fting it carefully away from the locating pins CAUTION The coal bed is extremely fragile and must be handled accordingly Gloves should be worn and any inhalation of the dust should be avoided Keep the coals away from children at all times Please read the Important Information Section on page 2 On re assembly ensure that the coal bed is correctly located over the locating pins BURNER Figs 10 11 and...

Page 9: ... Glass Frame Assembly 155 758 040955 C Knob Gas Tap Control 156 431 234551 D Flame Failure Device Gas Tap E05 653 242512 E Piezo Unit Vernitron 66111 393 734 042941 F Electro Magnet Unit E01 617 239413 G Injector F11 Cat 18 230 381 879 092133 H Burner Aeromatic Baxi Special 155 949 043210 I Oxy pilot Assembly 350mm SIT OP 9402 378 914 236204 J Lead Electrode 378 915 236199 K Coal Bed 156 429 23514...

Page 10: ...Supplied By www heating spares co Tel 0161 620 6677 Ebony Super Baxi Heating Ltd Page 10 Fault Finding Chart Page 10 11 BAXI EBONY SUPER Gas Type G20 Natural Gas Click here for Helplines ...

Reviews: