GENERAL PRECAUTIONS
7KLV ERLOHU KDV EHHQ GHVLJQHG WR KHDW ZDWHU WR D WHPSHUDWXUH ORZHU WKDQ ERLOLQJ SRLQW DW DWPRVSKHULF SUHVVXUH ,W PXVW EH
FRQQHFWHGWRDFHQWUDOKHDWLQJV\VWHPDQGWRDGRPHVWLFKRWZDWHUVXSSO\V\VWHPDFFRUGLQJWRLWVSHUIRUPDQFHDQGSRZHURXWSXW
%HIRUHKDYLQJWKHERLOHULQVWDOOHGE\DTXDOL¿HGVHUYLFHHQJLQHHUPDNHVXUHWKHIROORZLQJRSHUDWLRQVDUHSHUIRUPHG
• Make sure that the boiler is adjusted to use the type of gas delivered by the gas supply. To do this, check the markings on the
packaging and the data label on the appliance.
•
0DNHVXUHWKDWWKHÀXHWHUPLQDOGUDIWLVDSSURSULDWHWKDWWKHWHUPLQDOLVQRWREVWUXFWHGDQGWKDWQRH[KDXVWJDVHVIURPRWKHU
DSSOLDQFHVDUHH[SHOOHGWKURXJKWKHVDPHÀXHGXFWXQOHVVWKHODWWHUKDVEHHQVSHFLDOO\GHVLJQHGWRFROOHFWH[KDXVWJDVIURP
PRUHWKDQRQHDSSOLDQFHLQFRPSOLDQFHZLWKFXUUHQWODZVDQGUHJXODWLRQV
•
0DNHVXUHWKDWLIWKHERLOHULVFRQQHFWHGWRH[LVWLQJÀXHGXFWVWKHVHKDYHEHHQWKRURXJKO\FOHDQHGDVUHVLGXDOSURGXFWVRI
FRPEXVWLRQPD\GHWDFKIURPWKHZDOOVGXULQJRSHUDWLRQDQGREVWUXFWWKHÀRZRIIXPHV
•
7RHQVXUHFRUUHFWRSHUDWLRQDQGPDLQWDLQWKHZDUUDQW\REVHUYHWKHIROORZLQJSUHFDXWLRQV
1. DHW circuit
1.1
,IWKHZDWHULVKDUGHUWKDQ)) PJFDOFLXPFDUERQDWHSHUOLWUHRIZDWHULQVWDOODSRO\SKRVSKDWHGLVSHQVHURUDQ
HTXLYDOHQWWUHDWPHQWV\VWHPFRPSOLDQWZLWKFXUUHQWUHJXODWLRQV
1.2
7KRURXJKO\ÀXVKWKHV\VWHPDIWHULQVWDOODWLRQRIWKHDSSOLDQFHDQGEHIRUHXVH
1.3
7KHPDWHULDOVXVHGIRUWKH'+:FLUFXLWFRPSO\ZLWK'LUHFWLYH(&
2. Heating circuit
2.1 New system:
%HIRUHLQVWDOOLQJWKHERLOHUWKHV\VWHPPXVWEHFOHDQHGDQGÀXVKHGWRHOLPLQDWHUHVLGXDOWKUHDGFXWWLQJVZDUI
VROGHUDQGDQ\VROYHQWVXVLQJVXLWDEOHRႇWKHVKHOIQRQDFLGDQGQRQDONDOLQHSURGXFWVWKDWGRQRWGDPDJHPHWDOSODVWLFDQG
rubber parts. To protect the system from scale, use inhibitors such as SENTINEL X100 and FERNOX protector for heating circuits.
8VHWKHVHSURGXFWVLQVWULFWFRPSOLDQFHZLWKWKHPDQXIDFWXUHUVLQVWUXFWLRQV
2.2 Existing system:
Before installing the boiler, drain the system and clean it to remove sludge and contaminants, using suitable
proprietary products. Recommended cleaning products are: SENTINEL X300 or X400 and FERNOX regenerator for heating
FLUFXLWV8VHWKHVHSURGXFWVLQVWULFWFRPSOLDQFHZLWKWKHPDQXIDFWXUHUVLQVWUXFWLRQV5HPHPEHUWKDWWKHSUHVHQFHRIIRUHLJQ
ERGLHVLQWKHKHDWLQJV\VWHPFDQDGYHUVHO\DႇHFWERLOHURSHUDWLRQHJRYHUKHDWLQJDQGH[FHVVLYHQRLVHRIWKHKHDWH[FKDQJHU
,QLWLDOOLJKWLQJRIWKHERLOHUPXVWEHFDUULHGRXWE\DQDXWKRULVHG6HUYLFH(QJLQHHUZKRPXVW¿UVWHQVXUHWKDW
•
7KHUDWHGGDWDFRUUHVSRQGWRWKHVXSSO\HOHFWULFLW\ZDWHUDQGJDVGDWD
•
7KDWWKHLQVWDOODWLRQFRPSOLHVZLWKFXUUHQWUHJXODWLRQV
•
7KHDSSOLDQFHLVFRUUHFWO\FRQQHFWHGWRWKHSRZHUVXSSO\DQGHDUWKHG
Failure to observe the above will render the warranty null and void. The names of the Authorised Service Centres are
indicated in the attached sheet. Prior to commissioning, remove the protective plastic coating from the boiler. Do not use
any tools or abrasive detergents to do this as you may damage the painted surfaces.
Do not leave any packaging (plastic bags, polystyrene, etc.) within the reach of children as they are a potential source of danger.
ENERGY-SAVING TIPS
Adjustment in the heating mode
$GMXVWWKHERLOHUÀRZWHPSHUDWXUHGHSHQGLQJRQWKHNLQGRIV\VWHP)RUV\VWHPVZLWKUDGLDWRUVVHWDPD[LPXPKHDWLQJZDWHUÀRZ
WHPSHUDWXUHRIDSSUR[LPDWHO\&DQGLQFUHDVHWKLVYDOXHLIWKHUHTXLUHGURRPWHPSHUDWXUHLVQRWUHDFKHG)RUV\VWHPVZLWK
UDGLDQWÀRRUSDQHOVGRQRWH[FHHGWKHWHPSHUDWXUHLQGLFDWHGE\WKHV\VWHPGHVLJQHU8VHWKH([WHUQDO6HQVRUDQGRU&RQWURO
3DQHOWRDXWRPDWLFDOO\DGMXVWWKHÀRZWHPSHUDWXUHWRDWPRVSKHULFFRQGLWLRQVRUWKHLQGRRUWHPSHUDWXUH7KLVHQVXUHVWKDWQRPRUH
KHDWWKDQWKDWHႇHFWLYHO\QHFHVVDU\LVSURGXFHG$GMXVWWKHURRPWHPSHUDWXUHZLWKRXWRYHUKHDWLQJWKHURRPV(YHU\H[WUDGHJUHH
FHQWLJUDGHPHDQVFRQVXPLQJDSSUR[LPDWHO\PRUH$OVRURRPDPELHQWWHPSHUDWXUHGHSHQGLQJRQKRZWKHURRPVDUHXVHG
)RUH[DPSOHWKHEHGURRPRUWKHOHDVWXVHGURRPVFDQEHKHDWHGWRDORZHUWHPSHUDWXUH8VHWKHSURJUDPPDEOHWLPHUDQGVHWWKH
QLJKWWLPHURRPWHPSHUDWXUHDWDSSUR[LPDWHO\&ORZHUWKDQWKDWGXULQJWKHGD\7KHUHLVQRDSSUHFLDEOHVDYLQJWREHDFKLHYHG
E\VHWWLQJLWDQ\ORZHU2QO\LQFDVHRIDSURORQJHGDEVHQFHVXFKDVDKROLGD\VKRXOGWKHWHPSHUDWXUHVHWSRLQWEHORZHUHG'R
QRWFRYHUUDGLDWRUVDVWKLVSUHYHQWVWKHDLUIURPFLUFXODWLQJFRUUHFWO\'RQRWOHDYHWKHZLQGRZVSDUWLDOO\RSHQWRYHQWLODWHWKHURRPV
but open them completely for a short period.
Domestic hot water
6HWWLQJWKHGRPHVWLFKRWZDWHUDWWKHUHTXLUHGWHPSHUDWXUHZLWKRXWPL[LQJLWZLWKFROGZDWHUVDYHVDORWRIPRQH\$GGLWLRQDO
KHDWLQJZDVWHVHQHUJ\DQGFUHDWHVDGGLWLRQDOVFDOH
BAXI
a leading European manufacturer of hi-tech boilers and heating systems, has developed
&64FHUWL¿HG TXDOLW\ PDQDJHPHQW ,62 HQYLURQPHQWDO ,62 DQG KHDOWK DQG
safety (OHSAS 18001) systems. This means that BAXI S.p.A. includes among its objectives the
safeguarding of the environment, the reliability and quality of its products, and the health and
safety of its employees.
Through its organisation, the company is constantly committed to implementing and improving
these aspects in favour of customer satisfaction.
Summary of Contents for COMPACT E
Page 30: ...7733595 01 05 19 118 S E C T I O N C...
Page 31: ...119 S E C T I O N C 7733595 01 05 19 A B C D E F 65 65 65 65 31 5 70 38 5 105 162 5 153 5 22...
Page 32: ...7733595 01 05 19 120 S E C T I O N D 25 mm...
Page 35: ...123 S E C T I O N F 7733595 01 05 19...
Page 36: ...7733595 01 05 19 124 S E C T I O N F 7715701...
Page 37: ...125 S E C T I O N G 7733595 01 05 19...
Page 39: ...127 7733595 01 05 19...