1) With the outer case assembled as in 'Outer Case' 14 remove the 2 screws securing the
thermostat cover to the facia panel.
2) Fit the input cable to the terminal strip and clamp using the cable grip provided and clamp the
incoming cable into the cable clips provided on the outer case side panel so as to avoid contact
with the hot combustion box surfaces.
3) Connect the 2 green and yellow earth wires halfway down the appliance wiring harness to the
combustion chamber earth point on the outer case support bracket.
4) Fit the socket at the end of the wiring harness to the plug attached to the burner feed pipe and
clip the wire to the cable clips provided.
5) Refit the thermostat cover to the facia panel.
6) Push the thermostat phial into the thermostat pocket and clip the capillary behind the retaining
clip (
).