40
Hysteresis Burner ON
Switching hysteresis for burner control – Fig. 61.
Factory setting:
5 K
Setting range:
0 – 20 K
Fig. 61
Hysteresis
Burner ON
Save
–
Yes
No
+
+
5
K
For the Service Technician
Number of burner starts
The number of burner starts of the FireWIN is displayed – Fig. 58.
Fig. 58
Fig. 59
Number of
burner starts
Back
1.350
Delivery time ignition phase
Fuel quantity in the ignition phase – Fig. 60.
Fig. 60
Delivery time
ignition phase
Save
–
Yes
No
+
+
120
s
Fuel quantity auger conveyor
The calculated fuel quantity (actual value) and the range is displayed in kg/h,
and can be adjusted – Fig. 59.
FireWIN
FW 90
FW 120
Actual
value
Factory setting:
Setting range:
6.0 kg/h
±2 kg of range
6.0 kg/h
±2 kg of range
Range
Factory setting:
Setting range:
6.0 kg/h
6.0 – 8.0 kg/h
6.0 kg/h
6.0 – 8.0 kg/h
Correc-
tion
Factory setting:
Setting range:
0
±5
0
±5
FireWIN
FW 90
FW 120
Factory setting:
120 s
100 s
Setting range:
100 – 150 s
80 – 130 s
4.5.1 Parameters
The following parameters can be selected with the
arrow buttons, then confirmed using the Choose button.
–
Number of burner starts
–
Fuel quantity auger conveyor
–
Delivery time ignition phase
–
Hysteresis Burner ON
–
Maximum value of set temperature
–
Set temperature ext. heating requirement
–
Type of pellet feed system
–
Operating time of suction turbine
–
Profile ash removal
–
Correction of cleaning interval
–
Air intake/exhaust flap
–
Limits for blower speed
–
Install display module
–
Language
–
Installation
Fuel quantity
Auger conveyor
Actual value
6.0 kg
Range
6.0 kg
Correction
0
Choose