Where can I fit the heater?
This heater can be fitted into fireplaces or surrounds where the following dimensions
are available.
Width
400mm - 450 mm (15.35 inches - 17.72 inches)
Height
555mm - 590 mm (21.9 inches - 23.2 inches)
Depth
At least 75mm (At least 3 inches)
On models with fascia that are not held in place with magnets there should be at least
30mm (1.2 inches) clearance between the top of the fascia and anything such as a shelf,
fireplace surround or mantel etc. This will allow the fascia to be lifted off or removed
during servicing. To check this gently place the fascia against the surface to which it is
to be fixed. Measure the distance from the top of the fascia.
Using the 75mm (3 inch) spacer kit supplied, the heater can also be used where a
fireplace opening or fireplace surround opening are not available i.e. a flat wall.
Important electrical safety.
The heater must
not
be located in front of or under an electrical socket, the socket must
always be accessible in order to disconnect the heater from the electrical supply for
maintenance and cleaning.
Important! This heater must be earthed.
!
The heater is supplied with a 3 pin 13 Amp fused re-wireable plug with 1mm² 3 core
cable.
!
The wires in the cable are coloured in accordance with the following code: -
Live = Brown
Neutral = Blue
Earth = Green / Yellow
!
The electric cable must be safely routed from the heater to an electrical socket.
Moving the cable guide.
At the base of the heater you will find an electric cable which runs through a
rectangular plastic cable guide. As supplied the cable guide is fitted into the rectangular
cut-out on the right side of the heater. If required, the cable guide can be removed and
put in the rectangular slot in the centre or left hand side of the heater. For removal and
fitting please see the following sections.