5
© Baxi Heating UK Ltd 2009
3.0 Fitting the Receiver
3.1
Fitting the Receiver
1. Remove the cover by inserting a
screwdriver and twisting as shown (Fig. 5).
2. Select a suitable position for fitting and
mark the wall through the backplate.
3. Drill & plug the wall. Secure the
Transmitter with the screws provided.
Boiler Application
(Fig. 6)
4. On the boiler remove the yellow link
wire from terminals 1 & 2 on the terminal
strip.
5. Connect the Receiver as shown in Fig. 6.
The Live & Neutral may be taken from the
boiler (as shown).
Baxi Ambiflo™ Heat Pump Application
(Fig. 7)
6. Connect the Receiver as shown in Fig. 7.
7. Use Controls Relay Board part no.
5132432 and read the instructions
supplied with it.
8. In both applications replace the
Receiver cover.
CAUTION
: 230V ! Do not remove the
Receiver cover unless the
electrical supply is isolated !
b
br
bk
bk
g/y
1
N
L
2
230V
16A
Max.
Antenna
Button
L.E.D.
Cover
16A
Max.
Relay 1
Fuse 1A max.
(not supplied)
A1
A2
3A Switched
Fused Spur
Fig. 5
Fig. 6
Fig. 7