10.8 Using the remote control handset.
1.
Keep the pilot burner at the "main burner on" position. Check the full range of main
burner heat settings using the remote control handset. In order to vary the flame effect
between High and Low positions, press, and keep depressed, either the High button, or
the Low button as appropriate (See figure 24).
The handset operates on
ultrasonic principles, and as
such it is not necessary to point
it directly at the fire.
2.
Use the handset to switch to
the pilot only setting by
depressing the Low button until
only the pilot flame remains
alight.
3.
In order to disable the
handset, but still leave the pilot alight, turn the pilot burner control knob to the ignition
position (2 in figure 23).
4.
Turn the fire off by rotating the pilot burner control knob to the OFF position (1 in
figure 23).
10.9 Inlet pressure check.
The appliance is pre-set to give the correct heat input
at the inlet pressure shown in section 2 of this guide.
No adjustment is necessary.
1.
Check the inlet pressure by fitting a pressure
gauge at the test point. The test point is on the inlet
‘T’ connector (See figure 25). Check the pressure
with the appliance alight and set at maximum output.
2.
After checking, turn off the appliance. Remove the
pressure gauge and replace the test point sealing
screw.
3.
Relight the appliance. Turn to the maximum
output position and test around the sealing screw for
gas soundness with a suitable leak detection fluid.
Page 27
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2006.
Figure 25. Pressure test point
Figure 24. Remote control handset.