For concealed connection only:
4.
Pierce the grommet to allow the pipe to pass through it.
The grommet should envelop the pipe. If the hole is larger
than the pipe, seal it with tape.
Do not pierce the grommet
unless the supply pipe is to pass through it
.
5.
The appliance is supplied with two fireback spacers.
Do
not fit the fireback spacers if the fire is to be installed into a
precast or clay flue block system as in section 3.2.3
. These
should extend backwards to ensure sufficient clearance from
the back of the fireplace. Remove the label and retaining
screws from the rear sides of the hotbox. Position the
fireback spacer as shown in figure 11. Secure the fireback
spacers using the screws removed previously and the two
supplied with the fire.
6.
This appliance is supplied with a flue restrictor for
use where the flue draught is excessive. The restrictor
must NOT be fitted where a precast flue or a flue liner
is used. For all other installations the restrictor should
be fitted. There may however, be certain exceptional
circumstances where fitting the restrictor causes the
fire to fail the spillage test. In such cases the restrictor
will have to be removed. After removal conduct the
spillage check again.
The restrictor is packed loose with the appliance and is
fixed with two screws (See figure 12).
Page 20
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2006.
Figure 12
.
Flue restrictor
Figure 11. Fireback spacers
Figure 10. ‘U’ Seals