3 APPLIANCE DATA
The appliance data label is on the inner face of the back panel at the lower left hand
side. It is visible when the fascia is removed.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and the
result is as below :
Model
Efficiency % (Gross)
341
79
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica Certification
services (0087). The efficiency value may be used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings.
Page 6
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Gas
Natural (G20)
Inlet Pressure
20mbar
Gross Heat Input
Control Setting
4
5.05kW (17,200Btu/h)
3
3.45kW (11,800Btu/h)
2
1.80kW (6,100Btu/h)
1
1.55kW (5,300Btu/h)
Burner Test Pressure (Cold)
17.2 + 0.75mbar
(6.9 + 0.3in w.g.)
Gas Connection
8mm pipe
Burner Injectors
Upper
Bray Cat. 99 Size 115
Lower
Bray Cat. 99 Size 230A
Pilot & Atmosphere Sensing Device
SIT Ref. OPNG9419
Ignition
Piezo-electric
integral with gas tap
Aeration
Non-adjustable