background image

Page 13

Installation and Operating Instructions

ZR-DC/WBX

TESTING AND COMMISSIONING

MAINS VOLTAGES MAY NOW BE PRESENT. THERE IS A RISK OF INJURY OR DEATH BY  ELECTRIC SHOCK.

Check that all connections to your ZR-DC/WBX are correct then switch on the power to your camera, transmitter and ZR-

DC/WBX.

TESTING THE VIDEO AND TELEMETRY RECEPTION

Your ZR-DC/WBX switches to the type of telemetry it first receives when the power is switched on. You can still use the

video connections if you are using twisted-pair telemetry.
The Telemetry and Video Status LED located on the main PCB (see figure 1) is used to check that both the video and

telemetry signals are correct. Correct operation is indicated by a slow regular flash. Other fault conditions are shown

below.

If the video signal level is too low when it arrives at the transmitter then the telemetry can lose synchronisation causing

DATA ERRORS. To remedy this, adjust the video gain and lift potentiometers as shown below.

VIDEO GAIN AND LIFT ADJUSTMENT

Adjustments to the Gain and Lift potentiometers can improve picture quality on the monitor and/or improve coaxial

telemetry reception. VR5 is used to adjust the video Gain and VR6 is used to adjust the video Lift. These are factory set

to 1 V pk-pk. If you have data errors, try adjusting Gain and Lift to improve the picture quality. When your ZR-DC/WBX is

receiving correct telemetry, the Telemetry and Video Status LED will emit a slow regular flash. The location and default

setting of VR5 and VR6 is shown below.

Summary of Contents for ZR-DC/WBX

Page 1: ...Please read this manual before installing your receiver ZR DC WBX DC Receiver Installation Instructions...

Page 2: ...tion and Operating Instructions IMPORTANT The first few pages of these instructions contain important information on safety and product conformity Please read and ensure that you understand this infor...

Page 3: ...eedback Potentiometers 8 Pan and Tilt head feedback potentiometers 9 Connecting the Telemetry 10 Connecting the Video 10 Connecting the Alarm Inputs 10 Connecting the Alarm Output Relay 10 Switch Sett...

Page 4: ...for use in a general purpose CCTV installation and has no other function Do not exceed the voltage and temperature limits given in the specifications Only use your ZR DC WBX in a clean dry dust free...

Page 5: ...R LAYOUT Shown below are the locations of the connectors switches LEDs fuses etc on the main and preset printed circuit boards Although shown separately for clarity the preset PCB is usually mounted a...

Page 6: ...ds to be returned for whatever reason The packaging should contain The ZR DC WBX receiver These instructions Please inform your suppliers and carriers immediately if the product is damaged or any part...

Page 7: ...devices operated by the system Typical Connections CONNECTING THE PAN TILT HEAD AND AUXILIARIES Referring to the instructions for your Pan Tilt head and auxiliaries connect them according to the sche...

Page 8: ...the feedback pots For example it shows that as the lens is focused on a nearby object the focus feedback signal increases towards 5V The focus zoom and pan directions can easily be reversed using swit...

Page 9: ...pply connection Connect the wires to CON 1 according to the following Pan potentiometer to terminal 5 Tilt potentiometer to terminal 4 Checking correct feedback potentiometer operation Set the DVM to...

Page 10: ...O IN and the transmitter to VIDEO OUT Note In order for the auto pan and preset tour functions to operate correctly the video from the camera must be routed through the receiver PCB CONNECTING THE ALA...

Page 11: ...UTPUT RELAYS The AUX A AUX B AUX C and AUX D relays can be programmed to respond to camera power wipe lamps wash or Aux 4 telemetry commands from the transmitter The contact configuration is shown bel...

Page 12: ...o pan or Tour Auto pan is a software driven function and so does not need a specialised pan and tilt unit When you operate auto pan the Pan Tilt head pans for 60 seconds pauses 15 seconds pans in the...

Page 13: ...ct Correct operation is indicated by a slow regular flash Other fault conditions are shown below If the video signal level is too low when it arrives at the transmitter then the telemetry can lose syn...

Page 14: ...the position as preset n using the appropriate method for the transmitter or keyboard being used This is normally done by pressing the following keys in sequence F the function key n a number for the...

Page 15: ...y Inputs Baxall Coaxial Telemetry or 20mA current loop twisted pair to the Baxall Telemetry specification Video Input 1V peak to peak composite video via 75 ohm BNC connector Video Output 1V peak to p...

Page 16: ...e 5 10 00 Baxall Limited Stockport England Visit our Web site http www baxall com Baxall Limited reserve the right to make changes to the product and specification of the product without prior notice...

Reviews: