Installation Instructions
CDR Series
9
POWER SUPPLY CONNECTION
These cameras are fitted with a power supply that operates between 11-40 V DC and 18-
30 VAC. Connections and polarity are indicated adjacent to the terminals on the rear panel.
The power supply must be a class 2 isolated type
. The green POWER LED on the rear
panel indicates when power is connected.
Note
This product has an initial current demand on power up of 2 Amps.
VIDEO CONNECTIONS
Composite Video
To obtain a video output connect a video coaxial-cable terminated by a 75 Ohm BNC
connector to the BNC socket marked VIDEO OUT on the rear of the camera.
S-Video
An S-Video output is provided giving a Y/C separated video signal. The 4-pin mini-DIN
connector has the following specification: Y=1V pk-pk, 75 Ohm; C=0.3V, 75 Ohm
Genlock (external synchronisation)
For external synchronisation, connect a video coaxial cable, terminated with a 75 Ohm
BNC connector, to the socket marked GENLOCK on the rear of the camera. The GENLOCK
facility synchronises to either a 1V pk-pk video signal or a standard sync plus blanking
signal. A signal connected to the GENLOCK input automatically overrides all other
synchronisation settings.
Note
When using a master signal to synchronise multiple cameras, only one of the cameras
should have the genlock termination switched on, all the other cameras should have it
switched off. See
Sync Menu
on page 36.
COMMS I/O CONNECTIONS
1
Ground
2
Ground
3
Luminance
4
Chrominance
1
2
3
4
1
2
3
4
5
6
7
8
9
1.
RS485+
2.
RS485-
3.
20mA
4.
20mA
5.
GND
6.
Profile Switch
7.
Spare
8.
Spare
9.
Spare