5.5
Non isolated DTE Interface
This interface can be used to connect a standard serial device or to configure or debug
the InduBox GSM M4. This interface is accessible via a RJ-45 8-pin connector, is not
galvanically isolated and has all standard V.24 interface lines. A RJ-45 to a standard
female DB-9 connector cable is available.
PIN V.24
Description
Direction
Level
1
DCD Data Carrier Detect
DCE
DTE
V.28
2
RXD Receive Data
DCE
DTE
V.28
3
TXD
Transmit Data
DTE
DCE
V.28
4
DTR Data Terminal Ready
DTE
DCE
V.28
5
GND Ground
-
-
6
RI
Ring Indicator
DCE
DTE
V.28
7
RTS
Request to Send
DTE
DCE
V.28
8
CTS
Clear to Send
DCE
DTE
V.28
Power Supply