5.
Ports and Connectors
Before you start the installation, take a moment to become more familiar with the
possible connections to and from the InduBox GSM M4 modem.
The InduBox GSM M4 has three types of connectors; a mains terminal block screw
connector, two RJ-45 connectors and one FME connector.
Disconnect the mains power before connecting or
disconnecting the power and/or DTE plugs !
5.1
Mains Power Connection
PIN
1
N
2
L1
Always disconnect the mains power before connecting or disconnecting the power plug.
Make sure the voltage supplied to the modem is within range of the InduBox GSM M4
input voltage (see specifications for details on voltage range).
There is no fuse or circuit breaker built-in to the InduBox GSM M4, this must be added
externally.
When the InduBox GSM M4 modem is connected via a standard mains plug, the
used mains socket must be directly accessible and easy reachable.