Assembly
Operating Instructions CANsync-Master Option Module for BM4-O-PLC BM4-O-CAN-06
Document No.: 5.02056.01A
Baumüller Nürnberg Electronic GmbH & Co. KG
24
5.4
5.4
Assembly
1
Switch off the b maXX 4400 unit and secure it from being unintentionally restarted dur-
ing assembly.
2
Pull the cover forward from the controller section: you can now see the slots.
3
Look for the intended slot (
G
) on the controller section.
Figure 8:
Assembly
4
Turn the spagnolet locks above and below this slot by 90°. The spagnolet locks are
now horizontal.
5
Take out the front panel cover forward. Keep this cover. If you remove plug-in cards,
you must close the unit again using the cover.
DANGER
The following
will occur
,
if you do not observe this danger information:
m
serious personal injury
m
death
Danger from:
electricity.
The unit and the vicinity of the control cabinet may carry dangerous
voltages.
Before starting any work, ensure that the unit and its vicinity are free of voltage. Observe the
relevant safety regulations when handling current-carrying units.
CAUTION
The following
may occur
,
if you do not observe this caution information:
m
property damage.
Danger from:
electrostatic discharge.
The CANsync-Master option module for b maXX PLC
contains ESD components.
Observe the described ESD measures when handling the plug-in module.
Only hold the plug-in module by the gripping piece (see "C" in