36
Process
8.7
Interface
Digital IOs
8.7.1
Cameras of the Baumer SXG series are equipped with three input lines and three output
lines.
IO
8.7.1.1 Circuits
Notice
Low Active: At this wiring, only one consumer can be connected. When all Output pins
(1, 2, 3) connected to IO_GND, then current flows through the resistor as soon as one
Output is switched. If only one output connected to IO_GND, then this one is only us
-
able.
The other two Outputs are not usable and may not be connected (e.g. IO Power V
CC
)!
Output high active
Output low active
Input
Camera
Customer Device
IO Power VCC
U
ext
Pin
RL
IOUT
IO GND
Out (n)
Pin
Camera
Customer Device
IO Power VCC
RL
IOUT
IO GND
Out
U
ext
Pin (Out1, 2, 3)
Out1 or Out2
or Out3
Camera
Customer Device
IO GND
DRV
IN1 Pin
IN GND Pin
User Definable
8.7.1.2
Inputs
The wiring of these input connectors is left to the user.
Sole exception is the compliance with predetermined high and low levels (0 .. 4,5V low,
11 .. 30V high).
The defined signals will have no direct effect, but can be analyzed and processed on the
software side and used for controlling the camera.
The employment of a so called "IO matrix" offers the possibility of selecting the signal and
the state to be processed.
On the software side the input signals are named "Line0", "Line1" and "Line2".
(Input) Line0
state high
state low
(Input) Line1
state high
state low
(Input) Line2
state high
state low
Line0
Line1
Line2
IO Matrix
state selection
(software side)
Figure 41►
IO matrix of the
Baumer SXG on input
side.