20
6.5
Environmental Requirements
6.5.1 Temperature and Humidity Range for Storage and Operation
*)
Temperature
Storage temperature
-10°C ... +70°C ( +14°F ... +158°F)
Operating temperature*
+5 °C ... +60°C (+41°F ... +140°F)
Housing temperature
**)***)
max. +60°C (+140°F)
* If the environmental temperature exceeds the values listed in the table below, the cam-
era must be cooled. (see Heat Transmission)
Camera Type
Environmental Temperature
Monochrome
SXG10
+19°C (+66.2°F)
SXG20
+18°C (+64.4°F)
SXG21
+18°C (+64.4°F)
SXG40
+16°C (+60.8°F)
SXG80
+14°C (+57.2°F)
Color
SXG10c
+20°C (+68°F)
SXG20c
+20°C (+68°F)
SXG21c
+20°C (+68°F)
SXG40c
+19°C (+66.2°F)
SXG80c
+19°C (+66.2°F)
Humidity
Storage and Operating Humidity
10% ... 90%
non condensing
T
6.5.2 Heat Transmission
Caution
Provide adequate dissipation of heat, to ensure that the temperature does
not 60°C (+140°F).
The surface of the camera may be hot during operation and immediately
after use. Be careful when handling the camera and avoid contact over a
longer period.
As there are numerous possibilities for installation, Baumer does not specifiy a specific
method for proper heat dissipation, but suggest the following principles:
operate the cameras only in mounted condition
▪
mounting in combination with forced convection may provide proper heat dissipation
▪
*)
Please refer to the respective data sheet.
**)
Measured at temperature measurement point (T).
***)
Housing temperature is limited by sensor specifications.
Figure 13 ►
Temperature mea-
surement point (T) of
Baumer SXG cameras.