Baumer
Functions
|
8
V2 | OM20/OM30 IO-Link
Operating Manual
37
Behavior with invalid measured
values:
far
Characteristic curve inverted:
no
Analog signal
Distance
Sdc
Sde
P1
P2
Behavior with invalid measured
values:
far
Characteristic curve inverted:
yes
Analog signal
Distance
Sdc
Sde
P1
P2
IO-Link parameter: Analog measurement field
Parameter name
Values
Description
AnalogSetting.Output Type
4 ... 20 mA,
2 ... 10 mA/
0 ... 10 VDC,
0 ... 5 VDC
Configuring the range of the analog output
Distance@Analog Min
-
Enter the min. limit of the analog measure-
ment range (in mm)
Distance@Analog Max
-
Enter the max. limit of the analog mea-
surement range (in mm)
Output Characteristic
Not Inverted,
Inverted
Inverting the analog output
Baumer commands –
Output Scale at Analog Min
-
Teach in min. limit of the analog measure-
ment range (alternatively to the Teach but-
ton)
Baumer commands –
Output Scale at Analog Max
-
Teach in max. limit of the analog mea-
surement range (alternatively to the Teach
button)
Baumer commands – Output
Scale is set to the possible max.
-
Set the analog measurement range to the
max. possible limits