8
|
Functions
Baumer
26
Operating Manual
OM20/OM30 IO-Link | V2
Option 2: Enter the filter length as a numerical value
If the predefined filter lengths are not suitable, an individual filter length can be entered for the
Moving Average
and
Moving Median
filters. Especially when it comes to applications without dy-
namic changes in distances, such as the verification of the position of an object, a greater filter
length can improve the performance of the sensor. You can specify the length of the
Moving Av-
erage
and
Moving Median
filters after selecting the
Custom
filter.
n
Moving Median
filter: 1 - 21 values
n
Moving Average
filter: 1 - 256 values
IO-Link parameter:
Filter
operating mode
Parameter name
Values
Description
Operation Mode.Precision
Filter
Standard
,
High
,
Very High
,
High-
est
,
Custom
n
Selection among predefined filters
(number of measured values per filter).
n
Custom
: Enter the filter length as a nu-
merical value.
MovAvgFilter.Custom Mov-
ing Average Length
-
n
Freely configurable filter length for
Mov-
ing Average
.
MovMedianFilter.Custom
Moving Median Length
-
n
Freely configurable filter length for
Mov-
ing Median
.