5
|
Installation instructions
Baumer
20
Operating Manual
OM20/OM30 IO-Link | V2
ü
û
Mounting for measuring objects with colored edges / different reflective characteristics of the
surface:
Align the sensor parallel to the colored edge to prevent measurement errors.
ü
û
Mounting near strong ambient light:
Prevent the ambient light from entering the detection range of the receiver.
ü
û
Mounting several sensors close to each other:
Prevent the detection ranges of the receivers from overlapping. Only the sensor’s own laser
spot may be in the detection range of the receiver.