Elektrischer Anschluss / Electrical connection
Baumer_ATD2A_II_DE-EN_1707.indd
17
• I
OUT
: Current output increasing at
clockwise rotation when looking at
the mounting side.
• GND
OUT
: Reference voltage for
analogue output.
• Reset: Reset input for setting zero
position value at any desired point
within the entire resolution. The re-
setting process is triggered by ap-
ply of +UB.
• V/R: V/R counting direction input.
This input is standard on High.
V/R means increasing values with
clockwise shaft rotation when loo-
king at the mounting side. V/R-Low
means decreasing values with
clockwise shaft rotation when loo-
king at the mounting side.
• Error: Diagnostic output (Open
Collector with internal 10 kΩ pul
-
lup-resistor). The output is low-ac-
tive, that means if no fault submit-
ted, the output is +UB.
8.5
Assignment of the connec-
tion cables
• The assignment of the respective
connecting cables are to be taken
from the suitable data sheets!!!
• I
OUT
: Stromausgang steigend bei
Drehung der Welle im Uhrzeiger-
sinn mit Blick auf die Anbauseite.
• GND
OUT
: Bezugspotential für Ana-
logausgang.
• Reset: Reseteingang zum Nullset-
zen des Positionswertes an jeder
beliebigen Stelle innerhalb der Ge-
samtauflösung. Der Reseteingang
wird durch Auflegen von +UB aus
-
gelöst.
• V/R: Vor-/Rück-Zählrichtungsein-
gang. Unbeschaltet liegt dieser
Eingang auf High. V/R-High be-
deutet steigende Werte bei Dreh-
richtung der Welle im Uhrzeiger-
sinn bei Blick auf die Anbauseite.
V/R-Low bedeutet fallende Werte
bei Drehung der Welle im Uhrzei-
gersinn bei Blick auf die Anbausei-
te.
• Error: Diagnoseausgang (Open
Kollektor mit internem 10 kΩ Pul
-
lup-Widerstand). Der Ausgang ist
low-aktiv, d. h. wenn kein Fehlerfall
vorliegt, ist der AUB.
8.5
Belegung der Anschlusska-
bel
• Die Belegung der jeweiligen An
-
schlusskabel sind den entspre-
chenden Datenblättern zu entneh-
men!!!