o
The brass links must be positioned as marked in the appropriate
diagram and once established ALL terminal screws must be
tightened down firmly.
o
If when the hob is first switched on, only one of the zones
work, you should recheck that the terminal screws are all
fully tightened between the links. This should be done
before contacting the Baumatic Service Department.
o
The cable can be looped if necessary, but make sure that is not
kinked or trapped when the hob is in position. Care must be
taken to avoid the cable being in contact with hot parts of the
appliance.
Replacing the mains supply cable
If the mains supply cable is damaged, then it must be replaced by an
appropriate replacement which can be obtained from the Baumatic
Spares Department.
The mains supply cable should be replaced in accordance with the
following instructions:
o
Switch the appliance off at the control switch.
o
Open the terminal block on the underside of the hob.
o
Unscrew the terminal screws fixing the cable.
o
Replace the cable with one of the same length and in accordance
with the specification given above.
o
The “green-yellow” earth wire must be connected to the terminal
marked
. It must be about 10 mm longer than the live and
neutral wires.
18
Summary of Contents for PVC2SS Pythagora
Page 1: ...1 PVC2SS Pythagora 30cm 2 hyperspeed zone ceramic domino hob...
Page 23: ...23...