background image

KCGT 6010/I

Instructions for use

5019_718_02011_UK  30-05-2007  10:05  Pagina 1

Summary of Contents for KCGT 6010/I

Page 1: ...KCGT 6010 I Instructions for use 5019_718_02011_UK 30 05 2007 10 05 Pagina 1 ...

Page 2: ...5019_718_02011_UK 30 05 2007 10 05 Pagina 2 ...

Page 3: ...eguarding the environment 5 Instructions for installation and use 6 Extraction modes 6 Installation 7 Hood description 9 Functioning 9 Maintenance 10 After Sales Service 11 5019_718_02011_UK 30 05 2007 10 05 Pagina 3 ...

Page 4: ...ight bulbs make sure they have cooled down Note always use gloves when installing or carrying out maintenance work Electrical connection The mains voltage should correspond with the voltage shown on the specifications label found inside the hood If there is no plug connect the hood to a socket that complies with current legislation and is in an easily accessible location If there is no plug direct...

Page 5: ...stic bags polystyrene parts etc out of reach of children as they are potentially dangerous 2 Product This appliance is marked according to the European Directive 2002 96 EC Waste Electrical and Electronic Equipment WEEE By ensuring that this product is disposed of correctly you will help prevent potentially negative consequences for the environment and human health The symbol on the product or on ...

Page 6: ...ion Mode This mode is to be used when it is not possible to vent the air to the outside Air is purified by passing through activated charcoal filters not provided and recirculated back out into the kitchen The air is sent back into the atmosphere via a pipe that passes through the cupboard cabinetry and is connected to the connector ring Fig 2 Installation The minimum distance between the upper pa...

Page 7: ...sconnect and remove the surrounding units and those near the installation area of the hood so that you have better accessibility to the ceiling wall where the hood is to be installed Otherwise protect the units as much as possible and all the parts relating to the installation Choose a flat surface and cover it with some protection where you can place the hood and parts Disconnect the hood by turn...

Page 8: ...rd with 8 screws The frame on the box has more than 8 slots for passing the screws through use the most suitable ones for your installation making them as equidistant as possible Fig 5 Remove the grease filter and hook the filter support frame onto the hood At this stage connect up the electrics on the control panel and the lights Hook the filter support frame onto the hood snap fitting onto the t...

Page 9: ... speed button 1 4 Extraction speed button 2 5 Extraction speed button 3 6 Intense extraction ON OFF speed button lasts about 5 minutes after which the hood returns to previously selected extraction speed 7 Timer ON OFF button pressing this button can limit the running duration of the extraction selected as follows Speed 1 for 20 minutes Speed 2 for 15 minutes Speed 3 for 10 minutes Intensive speed...

Page 10: ...carbon filter varies depending on the installation usage and how often the grease filters are cleaned In any case the cartridge must be replaced at least once every four months Fitting dismantling the carbon filter Remove the grease filter unhook the filter support frame taking care to disconnect the control panel and lights see Fig 5 Attach a carbon filter on each side to cover both the protectio...

Page 11: ...plate inside the hood and visible when you remove the grease filters your full address your telephone number and area code the service code number below the word SERVICE on the rating plate inside the hood behind the grease filter If repair work has to be carried out contact the Customer Care Centre this is a guarantee that original spare parts will be used and a proper repair job done Failure to ...

Page 12: ...the colour embossed in words on the base of the plug Replacement fuse covers are available from your local electrical store For the Republic of Ireland only The information given in respect of Great Britain will frequently apply but a third type of plug and socket is also used the 2 pin side earth type Socket outlet plug valid for both countries If the fitted plug is not suitable for your socket o...

Page 13: ...5019_718_02011_UK 30 05 2007 10 06 Pagina 13 ...

Page 14: ...5019_718_02011_UK 30 05 2007 10 06 Pagina 14 ...

Page 15: ...5019_718_02011_UK 30 05 2007 10 06 Pagina 15 ...

Page 16: ...5019 718 02011 Printed in Italy n 05 07 GB 5019_718_02011_UK 30 05 2007 10 06 Pagina 16 ...

Reviews: