My appliance isn’t working correctly
Error codes
o
The burners will be shut down when the hob has tried three
consecutive times to ignite the burner without success.
Solution:
Execute the following key sequence for release:
o
The burner can be released by pressing the relevant minus
button and the safety lock button
(2)
simultaneously for at least
two seconds.
o
When released, the burner will be restored to level 0 and is
ready to be reignited.
For suggestions regarding why a burner may fail to ignite please see
the table below:
Reason Solution
There is no gas.
Check that the tap is open.
Incorrect connection to the
earthing system.
Check the connections.
The electrode does not find
the connection.
Check that the burner cover is
positioned properly in its seat.
o
The electronic circuit detects the presence of an abnormal or
parasite flame.
o
The electronics detect the presence of the flame before having
opened the gas valve and enters a “parasite flame” state and a
flashing “F” appears on the display. If this situation continues for
more than ten seconds, the burner will shut down.
o
Another condition for the parasite flame can be a failed valve
seal. This is the condition of wanting to ignite burner A but there
is a leak in burner B so both burners will be ignited.
o
Detecting the presence of a parasite flame for more than ten
seconds in a burner for which ignition is not requested, the
electronics will create a general shutdown state.
Solution:
Contact the Baumatic Ltd customer care helpline.