Purification Systems
Page 75
3rd Edition, Rev 0 Chg 6
5.3.2.2
Chamber
To change the cartridge, proceed as follows. See Figure 5-11
1. Depressurize the system by means of the bleed valve.
2. Unscrew the filter head using the special wrench supplied.
3. Screw the supplied T-wrench onto the threaded rod in the top of the cartridge. Pull out the cartridge
with the T-wrench.
4. Dispose of the dirty cartridge in accordance with local, state, and federal regulations.
5. Dry the inside of the chamber with a clean cloth and check for corrosion.
6. Replace all corroded parts with new BAUER parts.
7. Remove the shipping covering from the new cartridge and remove the protective cap from the bot-
tom of the cartridge.
8. Lubricate the O-rings with white petroleum jelly. Apply sparingly.
9. Firmly install the new cartridge. Be sure the cartridge snaps into place.
10. Reinstall the filter head.
11. Close the bleed valve, restore the power and reconnect the inlet supply line, if applicable.
Figure 5-10
Oil and Water Separator
1. Filter Head
2. Sintered Metal Filter
3. Acorn Nut
4. Hex Nuts