MNL-0096
April 17, 2013
Page 28
4. Dry the inside of the chamber with a clean cloth and check for corrosion.
5. Replace all corroded parts with new BAUER parts.
6. Remove the shipping covering and the protective cap from the bottom of the cartridge.
7. Lubricate the O-rings with white petroleum jelly. Apply sparingly.
8. Install the new cartridge. Be sure the cartridge snaps into place.
9. Reinstall the chamber head.
10. Close the bleed valve, restore the power and reconnect the inlet supply line, if applicable.
4.4.2.1
Leaking at the Safety Bore
1. Remove the cartridge following steps to 3. in Paragraph 4.4.2.
2. Install cartridge if missing.
3. Remove cartridge and inspect O-rings.
4. Replace O-rings if necessary.
5. Ensure protective caps and devices have all been removed.
6. Replace cartridge following steps 7. to 10. in Paragraph 4.4.2
Figure 4-6
Cartridge Replacement
NOTICE
If air is detected bleeding out from the bottom of the chamber, the cartridge has not been installed
properly or is missing. Follow the instructions in Paragraph 4.4.2.1