ENGLISH
pag. 57
instruction manual
for use and maintenance serie MEC, STAR, AGRI
11.6 TECHNICAL ASSISTANCE
Contact the supplier of the complete system for technical assistance or supply of accessories and spare parts.
11.7 REGULAR SERVICING
SERVICING TO BE CARRIED OUT
HOW TO PROCEED
FREQUENCY
Check oil circulation
Inspect the level sight glasses
Once a day
Check oil level in tank
Use the oil level on outside of tank
Once a week
Check wear of blades
Remove threaded plug
Every 300 working hours
Check that the over-pressure and vacuum
regulator valves are working correctly
Remove valves
Once a week
Wash oil tank
Remove tank
Once a year
Wash body internally
Put in oil + diesel oil (after washing
lubricate with oil only)
Whenever sewage enters or when
inactive for a long time
Wash lubrication pump
Use a brush and compressed air
Once a year or for prolonged
inactivity
Check that the overflow valves are
working correctly
Remove valves
Once a month
Lubricate the power take-off
(versions M - MA - K - KA and D)
Oil the P.T.O. with a brush and lubricating
oil
Once a month
Wash and clean the valves
Remove valves
Once a month
12 - PUTTING OUT OF SERVICE AND DEMOLITION
Before demolishing the Rotary blades vacuum pump the following materials should be separated:
•
lubricating oil;
•
parts in rubber and plastic;
•
parts in cast iron and steel;
and disposed of correctly.
Do not discard the Rotary blades vacuum pump in the environment.
For disposal of the lubricating oil make use of specialised treatment services.