DETAILED SPECIFICATIONS -
VDC Model No. E12248-AA-S2 (con’t.)
• Charging Output Control Characteristics
• Charging Flow : Battery condition detect>Soft Start
Charge>Bulk Charge>Absorption Charge>Sulfate
Check>Float Charge
• Soft Start Charging Activity conditions:
Battery Voltage is over Vdc and less than 10.5Vdc
• Soft Start Charging output current control:
(8A mode) 4 ±0.25 Adc
• Soft Start Charging Time Limited: (Stops charge if battery
cannot be charged over 10.5V after 6 hrs, Error LED flash
indicated) 6 ±0.25 Hours
• Bulk Charging Activity conditions:
Battery Voltage is over 10.5Vdc
• Bulk Charging Current control at 8A mode:
4 +0.22 / -0 Adc
• Max. rated output voltage and current:
1.0V at 8Adc 1.6V at 6.50Adc
• Bulk Charging Time Limited:
(Stops charge if battery cannot be fully charged [14.1V*]
after 20 hrs, error LED flash indicated) 20 ±1 Hours
*At 24°C