Rev. A-051007
P/N VDC36271-MNL
BatteryMINDer
®
Model 36271
Page 30
DETAILED SPECIFICATIONS - VDC Model No. 36271 (con’t.)
Charging Output Control Characteristics
Charging Flow : Battery condition detect> Soft Start Charge>Bulk Charge>Absorption Charge>
Sulfate Check>Float Charge
Soft Start Charging Activity conditions: Battery Voltage is over 9-Vdc and less than 31.5-Vdc (charger
will start in Gel mode automatically)
Soft Start Charging output current control: 0.7 ±0.25 Adc
Soft Start Charging Time Limited: (Stops charger if battery cannot be charged over 31.5-V after 6-
hours (Error LED flashes) 6 ±0.25 Hours
Bulk Charging Activity conditions: Starts when Battery Voltage is over 31.5-Vdc (charger will start Gel
mode automatically)
Bulk Charging Current control: 2.7 +0.3 / -0 Adc
Max. rated output voltage and current: 39.0V at 2.7Adc
43.8V at 2.5Adc
Bulk Charging Time Limited: (Stops charger if battery cannot be charged to 42.3 / 43.2 / 43.8-V within
20 hours (Error LED flashes) 20 ±1 Hours