The chart below shows the need to regulate the output voltage of the charger to ensure against over or
under charging your battery over a wide range of temperatures. Using your At-the-Battery Sensor will
accomplish this better than any other known method.
Temperature Ranges
Charge Voltage
GEL / Flooded / AGM
Maintenance
- Float Voltage
>=120°F / >=49°C
40.5 / 41.4 / 42.0
38.4
±0.35
Vdc
110-120°F / 43-49°C
40.8 / 41.7 / 42.3
38.7 ±0.35
Vdc
100-110°F / 38-43°C
41.1 / 42.0 / 42.6
39.0 ±0.35
Vdc
90-100°F / 32-38°C
41.4 / 42.3 / 42.9
39.3
±0.35
Vdc
80-90°F / 27-32°C
42.0 / 42.9 / 43.5
39.6
±0.35
Vdc
70-80°F / 21-27°C
42.3 / 43.2 / 43.8
40.2 ±0.35
Vdc
60-70°F / 16-21°C
42.9 / 43.8 / 44.4
40.8 ±0.35
Vdc
50-60°F / 10-16°C
43.2 / 44.1 / 44.7
41.1 ±0.35
Vdc
40-50°F / 4-10°C
44.1 / 45.0 / 45.6
42.0 ±0.35
Vdc
<=40°F / <=4°C
44.4 / 45.3 / 46.2
42.3 ±0.35
Vdc