BatteryMINDer
®
Model 483CEC1
Rev. A-051216
Page 16
P/N 483CEC1-MNL
too deeply discharged to be fully charged in the normal time allowed
by maintenance-charger. If you are certain battery set is not defective,
having read and understood completely all of the above concerns and
conditions, proceed to reboot the maintenance-charger by unplugging
from the wall (AC), disconnecting from the battery set (DC) and waiting
a minimum of 30 seconds before reconnecting the battery set and then
the AC. This allows maintenance-charger to begin charging battery set
again. If battery set is not defective it should be able to be fully charged
after being restarted. After sufficient time has lapsed the Float stage LED
Indicator (
Features
table, p. 10, item
2D
) will illuminate confirming when
/ if battery set is now fully charged.
OCV=Open Circuit No Load Voltage
OCV - “Rested” Voltage
Full Capacity
Percentage
48V
51.6 - 52.4
100%
50.4 - 51.6
75%
49.6 - 50.4
50%
48.8 - 49.6
25%
48.0 - 48.8
0%
<44 = shorted
EZC-01 Installation
The
EZC-01 Connector
is universal, flush-mountable
for use on any BatteryMINDer Charger-Maintainer;
it allows BatteryMINDers to be quickly connected or
disconnected from battery sets located in vehicles such
as golf carts, people movers, boats and more.
IMPORTANT INFORMATION ON USING PRODUCT
OUTDOORS: Always mount units in vertical position
with cord sets exiting downward to ensure weather tight
integrity and in clear sight so LED Indicators are always visible. Unit must be
mounted this way to ensure long term trouble-free life including weatherproof
integrity. Mounting in any other manner or using unmounted
(parallel to ground) except indoors may cause unit to fail
due to water intrusion that is unable to drain correctly.
For best connection use with BatteryMINDer Ring Terminal
assembly RTA-2415. Use 7/8" hole saw bit to install. Drill
small test hole to be sure no interference with other wires
or parts. Close protective cover securely to ensure water
tightness.