background image

Instruction Manual for  Part # NC5250PN,  

NC5250P, & NC5250PMAN

Aqua Sub

 Cart

Assembly Instructions:

1. The cart is partially assembled from the factory.  Attach the handle bar and hook up the wiring 

to the 24 DCM battery (not included). 

2. Connect the charger.  

A. The red wire of the two-wire set coming from the pump and the red wire from the charger 

must be connected to the positive post on the battery. 

B. The black wire of the two-wire set coming from the pump and the black wire from the 

charger must be connected to the negative post of the battery.

3. The handle bar fits into the brackets between the battery box and the tank.  With the handle 

pointing to the rear of the cart, fasten it in place with the supplied bolts.

Operation with Direct Fill Link Instructions:

The pump on the cart is equipped with an “on-off” switch and a built in pressure switch that is 

factory set.
1. Fill the tank with clean or deionized water through the lid on top of the tank.

 

Turn the pump 

switch on.

2. Remove dust cap on watering system and couple the male connector on the watering system 

with the female connector on the direct fill link. 

3. Squeeze the handle on the direct fill link to begin watering. You will see the flow indicator 

start spinning.  

4. When the flow indicator stops spinning and all indicator eyes on top of the valves rise to the 

top, release the handle and uncouple the connectors. 

5. Disconnect the tank after watering and replace dust cap on watering system. Never leave the 

tank connected after watering. 

6. Turn off when all batteries have been watered. 

Operation with Manual Gun Instructions:

1. Fill the tank with clean or deionized water through the lid on top of the tank. 
2. Remove battery caps.
3. Turn the pump switch on. 
4. Squeeze the handle on the manual gun to clear any air in the hose, dispensing water back 

into tank until there is uninterrupted flow. 

5. Insert the nozzle into the battery cell to be filled. Squeeze the trigger until the shut-off takes 

place. Gently tap the nozzle to prevent any drips. 

6. Remove the gun from the battery.  Repeat until all cells are filled. 
7. When watering is complete, turn off the tank and replace battery caps.

•  Always wear personal protective equipment (goggles, gloves, etc.) to 

protect yourself from sulfuric acid.

•  Only water after charging.
•  Do not use pump in an explosive environment.
•  Do not use tank to pump flammable liquids (gasoline, fuel, oil, etc.)
•  Read instructions in entirety before beginning the installation.

Summary of Contents for Aqua Sub NC5250PN

Page 1: ...English 1 2 Aqua Sub Cart Espa ol 3 4 Carretilla Aqua Sub Fran ais 5 6 Chariot Aqua Sub...

Page 2: ...ze the handle on the direct fill link to begin watering You will see the flow indicator start spinning 4 When the flow indicator stops spinning and all indicator eyes on top of the valves rise to the...

Page 3: ...nut to access this screen The tank should be empty while performing this otherwise you may have to tilt the tank backward so water will be away from the inlet location 2 Remove the screen and clean i...

Page 4: ...llenado directo para comenzar a irrigar Ver que el indicador de flujo comenzar a girar 4 Cuando el indicador de flujo deje de girar y los indicadores de las v lvulas se eleven hasta el tope suelte la...

Page 5: ...mole teada para llegar a esta malla El tanque debe estar vac o al relizar este procedimiento de otra forma deber voltearlo hacia atr s para que el agua se aleje de la entrada 2 Retire y limpie la mal...

Page 6: ...ncer tourner 4 Lorsque l indicateur de d bit arr te de tourner et tous les indicateurs visuels sur les valves sont remont s rel chez la poign e et d branchez les connecteurs 5 Replacez le bouchon anti...

Page 7: ...r l crou molet pour acc der l cran Le r servoir devrait tre vide lorsque vous effectuez ceci sinon vous devrez peut tre incliner le r servoir afin que l eau soit loin de l ouverture de l entr e d eau...

Page 8: ...336 714 0448 877 522 5431 6645 Holder Road Clemmons NC 27107 www batterywatering com AquaSub_INS_0618...

Reviews: