Battery Power Solutions Freedom CPAP Battery User Manual Download Page 6

Safety Warnings 

The following safety warnings are to be followed at all   mes! 



Do not drop, hit, crush, or otherwise cause any impact damage to the 
ba  ery as this may result in exposure of the cell contents. 

  Do not expose the ba  ery to open fl ames, heaters, incinera  on or  

other extreme heat, including long term exposure to direct sunlight, 
as exposure to extreme heat may result in a hazardous reac  on.

  Do not expose the ba  ery to moisture of any type.

  Do not disassemble or a  empt to repair the ba  ery, AC power supply 

or any other charging or connec  on components supplied by Ba  ery 
Power Solu  ons as there are no user-serviceable parts inside. 

  Do not use any AC power supply or other charging cable not supplied 

by Ba  ery Power Solu  ons for use with the Freedom™ ba  ery as   
doing so may result in a hazardous reac  on. 

  Do not charge the ba  ery on any fl ammable surface.

  Regularly  inspect  connec  on  cords  and   ps,  the  AC  power  supply, 

and any charging cables for damage or signs of wear and discon  nue 
use if damaged.

Warranty & Usage Disclaimer

  All Battery Power Solutions products are under warranty for  

manufacturing and quality defects for 1 (one) year. 

  This warranty does not cover damage resul  ng from modifi ca  on of 

or  improper  use  or  opera  on  of  the  product  that  is  not  consistent 
with the instruc  ons in this manual.

  By  purchasing,  using  or  possessing  any  Ba  ery  Power  Solu  ons               

product, you are agreeing to hold harmless Ba  ery Power Solu  ons, 
its  subsidiaries,  affi

  liates,  owners,  offi

  cers  and  employees  from  any 

and  all  claims  or  liability  for  any  damage  to  any  property  or  injury, 
illness or death of any person when such damage, injury, illness or 
death shall be caused in whole or in part from use of the product(s).

3

Summary of Contents for Freedom CPAP Battery

Page 1: ...Batteries to Power Your World USER MANUAL...

Page 2: ...ontrol Board Ini al Ba ery Usage Turning the Ba ery On O Charging the Ba ery Charging Interna onally General Charging Notes Charging Instruc ons Other Charging Op ons Powering Your PAP Device Respiron...

Page 3: ...em One M Series and DeVilbissIntelliPAPSeries ResMed Air 10 S9 Series Other PAP Devices Powering Other Devices Understanding Lithium Ion Ba eries Ba eryStorage Disposal FAQ General Troubleshoo ng 13 1...

Page 4: ...component see below Connec on Components Sold Separately Package Contents The following components are required to connect certain models of PAP devices to the Freedom ba ery These items are typicall...

Page 5: ...al grade rechargeable lithium ion cells LG brand Capacity 97 68 Wh Output Voltage Range 9V 12 6V DC USB Output Voltage 5V DC 2A Output Current 8A maximum DC Input Voltage Range 12 6V 17V AC Power Supp...

Page 6: ...reedom ba ery as doing so may result in a hazardous reac on Do not charge the ba ery on any ammable surface Regularly inspect connec on cords and ps the AC power supply and any charging cables for dam...

Page 7: ...n most cases and in some cases could actually prevent the ba ery from being able to power the device For op mal performance turn o heated humidi ca on and heated tubing Do not a empt to connect your P...

Page 8: ...ed together Single Ba ery 1 3 nights Dual Ba eries 3 5 nights A night is generally considered 7 5 hours For a list of speci c PAP device model average run mes please visit our website at www ba erypow...

Page 9: ...device is disconnected from the USB OUT port When not in use disconnect devices from the DC OUT jack or USB OUT port of the ba ery to allow the ba ery to completely shut down 6 Charging The Ba ery The...

Page 10: ...nd doesn t show a charge level disconnect the AC power supply press the charge level indicator bu on to illuminate the display screen then reconnect the AC power supply to resume the charging process...

Page 11: ...Freedom ba ery as doing so may result in a hazardous reac on 150W SINE WAVE POWER INVERTER The 150W Sine Wave Power inverter allows you to charge the ba ery via the cigare e lighter power socket of a...

Page 12: ...d humidi ca on and or heated tubing will signi cantly reduce run mes For op mal run mes turn these features o REQUIRED COMPONENTS Freedom CPAP Ba ery Kit DreamSta on 12V Power Adapter SINGLE BATTERY C...

Page 13: ...DC power pigtail cord into the DC OUT jacks of the ba eries Plug the 12V power adapter into the DC input port of the PAP device Turn the PAP device on and it should begin func oning The digital displa...

Page 14: ...r pigtail cord into the DC OUT jack of the ba ery Insert the appropriate connector p into the DC power pigtail cord System One 60 Series Tip with black top labeled W System One 50 M Series Tip with ye...

Page 15: ...p with black top labeled W System One 50 M Series Tip with yellow top labeled N Plug the DC power pigtail cord with appropriate connector p a ached into the DC input port of the PAP device Turn the PA...

Page 16: ...it ts either ResMed Air 10 or ResMed S9 series devices 13 Set the converter box and the appropriate output cord for your device aside Do not connect the output cord to the converter box yet as the con...

Page 17: ...x into the DC OUT jack of the ba ery Insert the appropriate output cord for your device Air 10 or S9 into the power converter box Plug the 24V power converter with appropriate output cord a ached into...

Page 18: ...d Insert the appropriate output cord for your device Air 10 or S9 into the power converter box Plug the 24V power converter with output cord a ached into the DC input port of the PAP device Turn the P...

Page 19: ...n be connected directly to the Freedom ba ery using the DC power pigtail cord and the connector p with the blue top labeled J included in the ba ery kit The connec on instruc ons will be the same as t...

Page 20: ...ing pages Instruc on sheets with images for the models listed above are available at www ba erypowersolu ons net under the speci ca ons tab for the Freedom ba ery Due to the ini al power draw required...

Page 21: ...ord into the DC OUT jack of the ba ery Plug the power inverter into the DC input cord Plug the AC power cord of the PAP device into the power inverter Plug the AC power cord into the PAP device Turn t...

Page 22: ...the AC power cord of the PAP device into the power inverter Plug the AC power cord into the PAP device Turn the PAP device on and it should begin func oning The digital display screen will show the c...

Page 23: ...m for your PAP device during power outages When you sleep you may leave your PAP device connected to the ba ery and then plug the ba ery into a wall outlet In the event AC power power from a wall outl...

Page 24: ...f the ba ery Plug the AC power supply into a wall outlet Plug the 12V power adapter into the DC OUT jack of the ba ery Plug the 12V power adapter into the DC input port of the PAP device The digital d...

Page 25: ...ries Plug the AC power supply into a wall outlet Plug the second DC power pigtail cord into the DC OUT jacks of the ba eries Plug the 12V power adapter into the second DC power pigtail cord Plug the 1...

Page 26: ...k top labeled W System One 50 M Series Tip with yellow top labeled N IntelliPAP Series Tip with blue top labeled J Plug the DC power pigtail cord with appropriate connector p a ached into the DC input...

Page 27: ...System One 50 M Series Tip with yellow top labeled N IntelliPAP Series Tip with blue top labeled J Plug the second DC power pigtail cord with correct connector p a ached into the DC input port of the...

Page 28: ...l outlet Plug the 24V power converter box into the DC OUT jack of the ba ery Insert the appropriate output cord for your device Air 10 or S9 into the power converter box Plug the 24V power converter w...

Page 29: ...outlet Plug the second DC power pigtail cord into the DC OUT jacks of the ba eries Plug the 24V power converter box into the second DC power pigtail cord Insert the appropriate output cord for your d...

Page 30: ...input cord into the DC OUT jack of the ba ery Plug the power inverter into the DC input cord Plug the AC power cord of the PAP device into the power inverter Plug the AC power cord into the PAP device...

Page 31: ...Plug the rst DC power pigtail cord into the DC IN jacks of the ba eries Plug the AC power supply into a wall outlet Plug the DC input cord into the second DC power pigtail cord Plug the second DC pow...

Page 32: ...eedom ba ery simultaneously however this could impact PAP device run mes DC INPUT CORD CONNECTION Plug the DC input cord into the DC OUT jack of the ba ery Plug the device DC power cord into the DC in...

Page 33: ...not su er the memory e ects that are associated with other types of ba ery chemistries This means the ba ery does not need to be completely discharged before charging Upon ini al use or a er prolonge...

Page 34: ...in the prescribed pressure se ng and thus be drawing more power from the ba ery PAP Device Type BiLevel devices will have lower run mes as the pressure se ng is not constant and changes throughout the...

Page 35: ...oning you can reset its internal circuitry by holding down the charge level indicator bu on for a full 10 seconds The digital display screen will ash and two dash marks will appear Release the bu on...

Page 36: ...1 877 445 5228 www ba erypowersolu ons net FREEDOM CPAP BATTERY USER MANUAL January 2018...

Reviews: