BATCHEN
Issue Date 2/11/01
QMAN0043 Installers Manual CII & C2000 Rev A.doc
- 22 -
Step 10:
Access "Communications Protocol" function. Use UP/DOWN keys to
select "EMAL", "giLb ELEct" or "giLb MPP" as appropriate.
Note:
See also section 6.2.
Step 11:
Access "Density" function; use the UP/DOWN and SHIFT DIGIT keys
to set LP Gas Density as required (510 to 580 - usually set to mid-point
of range of values expected for site).
Step 12:
Access "tcorr" function; use UP/DOWN keys to set Temperature
Compensation "On" or "Off" as required.
Step 13:
Access the "PrSt" function. Use UP/DOWN keys to select "EnAbL",
"diSAb" as appropriate.
Step 14:
Exit Calibrate functions.
Step 15:
Exit Function mode; displays should show:
Value:
"0.00"
Volume:
"0.00"
Price/Unit:
"NNN.NN"
If any problem is experienced see Fault Finding Guide in Service Manual.