Battery Charger MVD
User's Manual
PROGRAM CURVE : IU1 U2
Using this Program for the follow battery:
reading battery voltage 39.6 V
Press the buttons UP and DOWN simultaneously.
In the first step A
(3.A)
, the charger workes in current costant way
(I=K)
for the maximum time
of
(200 minutes)
with a current of
(25%Ah --> [800 Ah] 8*25 = 200 Amp),
and if the battery
voltage reache
(2.40 V/Cell)
before the end of the time, the charger will go to next step.
MVD-BASSI
Page 16 of 34
3.A I=K T= 200m
I=25%Ah V=2.40 V
3.B V=K T= 240m
I=3%Ah V=2.40 V
3.C V=K T=FULL
I=DIS V=2.25 V
3.D PAU T= DIS.
I= DIS. V= DIS.
3.E PAU T= DIS.
I= DIS. V= DIS.
3.F PAU T= DIS.
I= DIS. V= DIS.
39.6 V
800 Ah
EL= 18
PROG.03