Physical Interface
Basler scout light
35
Fig. 13: Typical Voltage Output Circuit
Figure 14 shows a typical circuit you can use to monitor the output line with an LED or an opto-
coupler. In this example, the voltage for the external circuit is +24 VDC. Current in the circuit is
limited by an external resistor.
Fig. 14: Typical LED Output Signal at +24 VDC for the External Circuit (Example)
By default, the camera’s exposure active (ExpAc) signal is assigned to output line 1. The exposure
active signal indicates when exposure is taking place.
The assignment of a camera output signal to the physical output line can be changed by the user.
For more information about output line pin assignments and pin numbering, see Section 5.2 on
page 24
.
For more information about the exposure active signal, see Section 6.8 on
page 61
.
Your Gnd
Your Gnd
270
Ω
Voltage
Output
Signal
to You
Gnd
I/O_Out_1
Out_1_Ctrl
220
Ω
I/O_Out_VCC
Q
BC847BS
D
BAS16
1
2
3
4
5
6
7
8
9
10
11
12
12-Pin
Receptacle
Camera
+3.3 to +24
VDC
Your Gnd
Your Gnd
2.2k
Ω
LED
Output
to You
Gnd
I/O_Out_1
Out_1_Ctrl
220
Ω
I/O_Out_VCC
Q
BC847BS
D
BAS16
1
2
3
4
5
6
7
8
9
10
11
12
12-Pin
Receptacle
Camera
+24 VDC
Summary of Contents for slA1000-30fm
Page 4: ......
Page 24: ...Software and Hardware Installation 16 Basler scout light...
Page 26: ...Tools for Changing Camera Parameters 18 Basler scout light...
Page 82: ...Image Acquisition Control 74 Basler scout light...
Page 106: ...I O Control 98 Basler scout light...
Page 140: ...Standard Features 132 Basler scout light...
Page 158: ...Troubleshooting and Support 150 Basler scout light...
Page 160: ...Revision History 152 Basler scout light...
Page 162: ...Feedback 154 Basler scout light...
Page 166: ...Index 158 Basler scout light...