POWER SUPPLY STATUS OUTPUT
The power supply status relay has a set of normally closed contacts and energizes when operating power
is applied to the BE1-59N. If relay operating power is lost or either side of the power supply output (+12
Vdc or –12 Vdc) fails, the power supply status relay de-energizes and opens the power supply status
output contacts.
POWER SUPPLY
Operating power for the relay circuitry is supplied by a wide range, electrically isolated, low-burden power
supply. Power supply operating power is not polarity sensitive. The front panel power LED and power
supply status output indicate when the power supply is operating. Power supply specifications are listed
in Table 1-1.
TARGET INDICATORS
Target indicators are optional components selected when a relay is ordered. The electronically latched
and reset targets consist of red LED indicators located on the relay front panel. A latched target is reset
by operating the target reset switch on the front panel. If relay operating power is lost, any illuminated
(latched) targets are extinguished. When relay operating power is restored, the previously latched targets
are restored to their latched state.
A relay can be equipped with either internally operated targets or current operated targets.
Internally Operated Targets
The relay trip outputs are directly applied to drive the appropriate target indicator. Each indicator is
illuminated regardless of the current level in the trip circuit.
Current Operated Targets
A current operated target is triggered by closure of the corresponding output contact and the presence of
at least 200 milliamperes of current flowing in the trip circuit.
NOTE
Prior to September 2007, BE1-59N target indicators consisted of magnetically
latched, disc indicators. These mechanically latched target indicators have been
replaced by the electronically latched LED targets in use today.
Summary of Contents for BE1-59N
Page 2: ......
Page 6: ...iv BE1 59N Introduction 9171400990 Rev G This page intentionally left blank ...
Page 8: ...vi BE1 59N Introduction 9171400990 Rev G This page intentionally left blank ...
Page 16: ...1 8 BE1 59N General Information 9171400990 Rev G This page intentionally left blank ...
Page 22: ...3 4 BE1 59N Functional Description 9171400990 Rev G This page intentionally left blank ...
Page 24: ...4 2 BE1 59N Installation 9171400990 Rev G Figure 4 1 Panel Cutting Drilling Semi Flush Case ...
Page 32: ...4 10 BE1 59N Installation 9171400990 Rev G Figure 4 9 Sensing Input Connections ...
Page 38: ...5 4 BE1 59N Testing 9171400990 Rev G This page intentionally left blank ...