BE1-50/51B-217 General Information
1-9
AUX Output
- Continued
Inductive:
120/240 Vac,
Make and carry 30 amperes for 0.2 seconds, carry 7 amperes
125/250 Vdc
continuously, and break 0.3 ampere. (L/R = 0.04).
Isolation
Meets IEC 255-5 and exceeds IEEE C37.90-1989, one-minute dielectric
(high potential) tests as follows:
All circuits to ground:
2828 Vdc
Input to Output Circuits
2000 Vac or 2828 Vdc
Surge Withstand Capability
Oscillatory
Qualified to IEEE C37.90.1-1989
5VCPFCTF 5WTIG9KVJUVCPF
%CRCDKNKV[59%6GUVUHQT2TQVGEVKXG4GNC[UCPF4GNC[5[UVGOU
Fast Transient
Qualified to IEEE C37.90.1-1989
Standard Surge
Withstand
Capability (SWC) Tests for Protective Relays and Relay
Fast Transient
Qualified to IEEE C37.90-1989.
Impulse Test
Qualified to IEC 255-5.
Radio Frequency
Field tested using a five watt, hand held transceiver operating at random
Interference (RFI)
frequencies centered around 144 megahertz and 440 megahertz, with the
antenna located six inches from the relay in both horizontal and vertical
planes.
Temperature
Operating Range
-40
(
C (-40
(
F) to 70
(
C (158
(
F)
Recommended Storage Range
-50
(
C (-58
(
F) to 50
(
C (122
(
F).
Shock
15 g in each of three mutually perpendicular planes.
Vibration
2 g in each of three mutually perpendicular planes swept over the range of
10 to 500 hertz for a total of six sweeps, 15 minutes each sweep.
Weight
8.6 pounds.
CHARACTERISTIC CURVES
Figures 1-7 through 1-15 illustrate the characteristic curves that are programmed into the nonvolatile
memory of this relay. To order full-size drawings of these characteristic curves, contact the Customer
Service Department of the Power Systems Group, Basler Electric, and request the 99-(4 digit) number
associated with each graph. These graphs are full size characteristic curves on transparent paper (vellum).
Summary of Contents for BE1-50/51B-217
Page 26: ...BE1 50 51B 217 Controls and Indicators 2 3 Figure 2 2 Location of Controls and Indicators...
Page 29: ...BE1 50 51B 217 Functional Description 3 3 Figure 3 1 Functional Block Diagram...
Page 31: ...BE1 50 51B 217 Installation 4 2 Figure 4 1 Panel Drilling Diagram S1 Case Semi Flush Mount...
Page 33: ...BE1 50 51B 217 Installation 4 4 Figure 4 3 Panel Drilling Diagram S1 Case Projection Mount...
Page 37: ...BE1 50 51B 217 Installation 4 8...
Page 40: ...BE1 50 51B 217 Installation 4 11 Figure 4 7 BE1 50 51B 217 Overcurrent Relay Rear View...