![Basler Vision Technologies Sprint Series User Manual Download Page 195](http://html1.mh-extra.com/html/basler-vision-technologies/sprint-series/sprint-series_user-manual_2707562195.webp)
Configuring the Camera
Basler sprint Mono Cameras
185
Lookup Table Value CSR
Register Base Address: 0x4111
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control and status register:
0x00 = The register is not available
0x01 = The register is available and all related settings are OK
0x80 = A value in the register is set out of range
Field Name:
Lookup Table Value
Offset
: 0x0001
Size:
1 Byte
Type
: Read/Write
Description:
Writing an integer to this field enters a value into the camera’s lookup table at the index currently
specified by the lookup table index CSR.
for more information about the lookup table feature.
Field Name:
Min
Offset
: 0x0002
Size:
1 Byte
Type
: Read only
Description:
Minimum allowed integer value for a lookup table value.
Field Name:
Max
Offset
: 0x0003
Size:
1 Byte
Type
: Read only
Description:
Maximum allowed integer value for a lookup table value.
Field Name:
Increment
Offset
: 0x0004
Size:
1 Byte
Type
: Read only
Description:
An integer value indicating the increment for the lookup table value.
Summary of Contents for Sprint Series
Page 4: ......
Page 10: ...Table of Contents vi Basler sprint Mono Cameras...
Page 42: ...Physical Interface 32 Basler sprint Mono Cameras Fig 14 Camera Frame Grabber Interface...
Page 48: ...Physical Interface 38 Basler sprint Mono Cameras...
Page 76: ...Line Acquisition Modes 66 Basler sprint Mono Cameras...
Page 94: ...Exposure Start and Exposure Time Control 84 Basler sprint Mono Cameras...
Page 230: ...Revision History 220 Basler sprint Mono Cameras...