Basler sprint Mono Cameras
Line Stamp High Pixel Threshold CSR
Register Base Address: 0x2B40
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control and status register:
0x00 = The register is not available
0x01 = The register is available and all related settings are OK
0x80 = A value in the register is set out of range
Field Name:
High Pixel Threshold
Offset
: 0x0001
Size:
2 Bytes
Type
: Read/Write
Description:
Writing an integer to this field sets the high pixel threshold for the line stamp feature.
When the camera is set for 8 bit output, you should set the high pixel threshold within a range from
0 (0x0000) to 255 (0x00FF).
When the camera is set for 10 bit output, you should set the high pixel threshold within a range
from 0 (0x0000) to 1023 (0x03FF).
When the camera is set for 12 bit output, you should set the high pixel threshold within a range
from 0 (0x0000) to 4095 (0x0FFF).
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the high pixel threshold
Byte 1 = High byte of the high pixel threshold
for more information about the line stamp feature and the high pixel
threshold.
Field Name:
Min
Offset
: 0x0003
Size:
2 Bytes
Type
: Read only
Description:
Minimum allowed integer value for the high pixel threshold. This field is updated to reflect
limitations caused by the way any related features are set.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the min value
Byte 1 = High byte of the min value
Field Name:
Max
Offset
: 0x0005
Size:
2 Bytes
Type
: Read only
Description:
Maximum allowed integer value for the high pixel threshold. This field is updated to reflect
limitations caused by the way any related features are set.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 1 = High byte of the max value
Field Name:
Increment
Offset
: 0x0007
Size:
2 Bytes
Type
: Read only
Description:
An integer value indicating the increment for the high pixel threshold setting.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the increment
Byte 1 = High byte of the increment
Summary of Contents for Sprint Series
Page 4: ......
Page 10: ...Table of Contents vi Basler sprint Mono Cameras...
Page 42: ...Physical Interface 32 Basler sprint Mono Cameras Fig 14 Camera Frame Grabber Interface...
Page 48: ...Physical Interface 38 Basler sprint Mono Cameras...
Page 76: ...Line Acquisition Modes 66 Basler sprint Mono Cameras...
Page 94: ...Exposure Start and Exposure Time Control 84 Basler sprint Mono Cameras...
Page 230: ...Revision History 220 Basler sprint Mono Cameras...