background image

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 

All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in 

electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. 

This publication represent the technical status at the time of printing. 
© Copyright 2017 by Conrad Electronic SE. 1529336_V1_0217_02_VTP_m_en

Preparation

Type labels in different languages are included in the package. Stick the language label in your 

language over the German language label on the LED mains outlet dimmer adapter.

Getting Started, Use

  Follow the safety instructions and the other information in this operation manual!

•  Turn off the LED mains outlet dimmer adapter by turning the control knob counter-clockwise 

until it stops and you can hear a click.

  You should always switch off the LED mains outlet dimmer adapter by means of the 

control knob first, before you plug it into a mains socket and connect the lamp!

•  Plug the LED mains outlet dimmer adapter into a standard earthed mains socket (wall socket).
•  Connect a suitable lamp that you can dim to the front of the LED mains outlet dimmer adapter.

  Check the operating instructions of the lamp which you intend to connect whether 

it is possible to dim the lamp. Note the minimum and maximum load capacity in the 

chapter “Technical Data”.

  

The LED mains outlet dimmer adapter switches off when overloaded. Once the 

overload has been removed (and the LED mains outlet dimmer adapter perhaps has 

cooled off), the LED plug-in dimmer can be used again.

 

If the lamp you are using comes with its own dimmer, do not connect it to the LED 

mains outlet dimmer adapter. This also applies if the lamp has a USB charging 

output for example.

•  When you turn the control knob to the right in a clockwise direction the lamp connected will 

switch on (if necessary, switch on the switch of the lamp).

•  The light of the connected lamp becomes ever brighter, the more you turn the knob to the 

right.

•  Turn off the LED mains outlet dimmer adapter by turning the control knob to the left in a 

counter-clockwise direction until it stops and you can hear a click.

  At times the light cannot be dimmed properly, although the manufacturer has marked 

the lamp, which you have connected to the LED mains outlet dimmer adapter, as 

“dimmable”.

 

It can happen that the light flickers at low brightness or flickering may occur at a 

particular dimmer position.

 

Some LED lights (although marked as “dimmable”) cannot be dimmed under a cer-

tain minimum brightness (for example, dimming is only possible between 60% and 

100%, but when it is less than 60%).

 

This is not a fault of the LED mains outlet dimmer adapter, but due to technicalities 

in the lamp’s electronics. Unfortunately, we cannot guarantee that the LED mains 

outlet dimmer adapter will dim a connected lamp properly due to the vast variety of 

different products.

Troubleshooting

The lamp connected is flickering 
•  Check whether the lamp can be dimmed (note the operating instructions for the lamp or, if 

applicable, the description on the lamp).

•  Use a higher/different dimmer position.
•  Pull out the lamp’s power plug from the LED mains outlet dimmer adapter and turn the plug 

by 180° and try plugging it back in (this reverses “L” and “N” of the lamp’s power plug). Check 

again the dimming function of the LED mains outlet dimmer adapter with the lamp connected.

•  Pull out the LED mains outlet dimmer adapter from the mains socket and turn the plug by 

180° and try plugging it back in (this reverses “L” and “N” of the lamp’s power plug). Check 

again the dimming function of the LED mains outlet dimmer adapter with the lamp connected.

The lamp connected does not light
•  Check whether the lamp can be dimmed (note the operating instructions for the lamp or, if 

applicable, the description on the lamp).

•  Use a higher/different dimmer position.
•  Switch on the lamp using the lamp’s own switch.
•  Use a different lamp. This lamp is not compatible with the LED mains outlet dimmer adapter.
After the LED lamp or the LED mains outlet dimmer adapter are turned off, the LEDs of 

the LED lamp are still glowing
•  Plug the LED mains outlet dimmer adapter into the socket with the plug turned by 180° and/

or the lamp’s power plug into the LED mains outlet dimmer adapter. This reverses “L” and 

“N” respectively.

The LED mains outlet dimmer adapter gets warm
•  The LED mains outlet dimmer adapter becomes warm, especially when lamps with higher 

power ratings are connected. This is normal.

Care and Cleaning

Before cleaning the product, unplug the lamp from the LED mains outlet dimmer adapter. Dis-

connect then the LED mains outlet dimmer adapter from the power supply by unplugging it 

completely from the mains socket.
Never use abrasive cleaning agents, cleaning alcohol or other chemical solutions, since these 

could damage the housing or even impair operation.
Use a dry, lint-free cloth to clean the product.

Disposal

  Electronic devices are recyclable material and do not belong in the household 

waste. Dispose of an unserviceable product in accordance with the relevant statu-

tory regulations.

Technical Data

Operating voltage ............................230 V/AC, 50 Hz
Power rating ....................................incandescent lamps/halogen lamps: 30 - 200 W

.........................................................

LED lamps: 3 - 24 W

  The LED mains outlet dimmer adapter is not suitable for energy saving lamps or 

fluorescent lamps.

Type of switch .................................. single-pole (dimmer off, control knob all the way to the left 

until it locks) 

Socket with child protection .............yes
Protection class ...............................I
Ambient conditions .......................... temperature 0 °C to +40 °C, air humidity <95% relative, 

non-condensing

Dimensions ......................................55 x 108.5 x 80.5 mm (W x H x D, including plug)
Weight .............................................102 g

Summary of Contents for 1529336

Page 1: ...cker Wenn der LED Steckdosen Dimmadapter Beschädigungen aufweist so fassen Sie ihn nicht an es besteht Lebensgefahr durch einen elektrischen Schlag Schalten Sie zuerst die Netzspannung für die Netzsteckdose ab an der der LED Steckdosen Dimmadapter angeschlossen ist zugehörigen Sicherungsautomat abschalten bzw Sicherung herausdrehen anschließend FI Schutzschalter ab schalten so dass die Netzsteckdo...

Page 2: ...n Dimmadapters sondern technisch be dingt durch die Elektronik in der Leuchte Aufgrund der Vielzahl an unterschied lichen Produkten kann leider nicht garantiert werden dass der LED Steckdosen Dimmadapter eine angeschlossene Leuchte korrekt dimmen kann Störungsbeseitigung Angeschlossene Leuchte flackert Prüfen Sie ob die Leuchte dimmbar ist Bedienungsanleitung der Leuchte beachten oder ggf Aufschri...

Page 3: ...plugged If the LED mains outlet dimmer adapter is damaged do not touch it there is a danger to life from electric shock First switch off the mains voltage to the socket to which the LED mains outlet dimmer adapter is connected switch off at the corresponding circuit breaker or remove the safety fuse or switch off at the corresponding RCD protective switch so that all poles of the mains socket are ...

Page 4: ...utlet dimmer adapter but due to technicalities in the lamp s electronics Unfortunately we cannot guarantee that the LED mains outlet dimmer adapter will dim a connected lamp properly due to the vast variety of different products Troubleshooting The lamp connected is flickering Check whether the lamp can be dimmed note the operating instructions for the lamp or if applicable the description on the ...

Page 5: ...resulteren in een over verhitting en eventueel tot brand kan leiden Spanningsloos alleen bij ontkoppelde stekker Is de LED Dimadapter voor contactdoos beschadigd Raak deze dan niet aan Uw leven kan door elektrische schokken gevaar lopen Schakel eerst de netspanning uit van de contactdoos waaraan de LED Dimadap ter voor contactdoos is aangesloten door de bijbehorende zekeringautomaat uit te schakel...

Page 6: ...sche beperking door de elektronica van de lamp Op basis van de vele verschillende pro ducten kan niet gegarandeerd worden dat de LED Dimadapter voor contactdoos een aangesloten lamp op de juiste manier kan dimmen Verhelpen van storingen Aangesloten verlichting flikkert Controleer of de verlichting dimbaar is gebruiksaanwijzing van de lamp controleren of op schrift op de lamp Gebruik een hogere and...