HYDRAULIC CONNECTIONS 

Check that the suction line does not exceed the maximum height of 1.5 m from the tank bottom. Unscrew the pipe-wrench 
nut and remove the two protective caps from fittings (in the case a pump head needs to be removed, it is recommended to 
reuse the protective caps, to prevent any leakage from the pump body). 

Note:

 If the product to be dosed is sulfuric acid, previously remove any water from the pump and use polyethylene pipes. 

 
All operations to tighten the pipe connections of the pumps must be done by hand, without using any tools (e.g. pliers 
squeeze tube), to avoid damaging the hydraulic connections. 

 

Suction Line

 

(also see drawing)

 

1.  Unscrew the fixing nut of the suction fitting (located on the bottom of pump 

head) and remove the protective cap.

 

 

2.  Cut the PVC Crystal, transparent tube. 
3.  Insert the pipe-wrench and tube-press on the tube. 
4.  Mount  the  tube  on  the  conic  hose  of  the  suction  fitting,  pushing  it  until  it 

reaches the stop collar. 

5.  Fix the tube by screwing the pipe-wrench nut onto the suction fitting of the 

pump head. 

6.  Locate the PVC Crystal tube inside the tank and/or the suction lance. 
7.  Unscrew the pipe-wrench nut of the foot filter. 
8.  Cut the PVC Crystal, transparent tube. 
9.  Insert the pipe-wrench on the tube. 
10.  Mount  the  tube  on  the  conic  hose  of  the  foot  filter  fitting,  pushing  it  until  it 

reaches the stop collar. 

11.  Fix the tube by screwing the pipe-wrench nut onto the foot filter fitting. 
12.  Screw  the  foot  filter  onto  the  suction  lance  (if  used)  and/or  locate  it  in  its 

working place. 

 

Notes: 

 

The foot filter must be located at a minimum distance of 5 cm from the tank bottom. 

 

If a dense product is dosed, it is recommended to remove the small inside filter from the foot valve, in order to facilitate 
the suction. 

 

Bleed Line 

1.  Cut the PVC Crystal, transparent tube. 
2.  Insert the tube on the bleed outlet, located on the right side of the pump head. 
3.  Insert the other end of the tube in the tank of the product to be dosed, in order to recover the product that comes out 

when the bleed valve is operated. 

Injection Line

 

(also see drawing)

 

1.  Unscrew the fixing nut of the head fitting (located on the top of the pump head) and remove the protective cap. 
2.  Cut the white, semi-rigid, PE tube. 
3.  Insert the pipe-wrench and tube-press on the PE tube. 
4.  Mount the tube on the conic hose of the pump fitting, pushing it until it reaches the stop collar. 
5.  Fix the tube by screwing the pipe-wrench nut onto the head fitting of the pump head. 
6.  Place the head tube avoiding as much as possible the curves and ensuring that it does not rub against rigid bodies for 

effect of the pulses. 

7.  Perform all electrical connections (see related section later in this manual) and power the pump. 
8.  At the injection point on the pipeline, mount a ½” GAS connection, internally threaded (not supplied). 
9.  Wrap PTFE tape to the thread and tighten the injection valve to the fitting. 
10.  Unscrew the pipe-wrench nut of the injection valve fitting. 
11.  Cut the white, semi-rigid, PE tube. 
12.  Insert the pipe-wrench on the PE tube. 
13.  Mount the tube on the conic hose of the injection valve, pushing it until it reaches the stop collar. 
14.  Screw the pipe-wrench nu tonto the valve fitting. 

 

Note:

 The injection valve also works as non-return valve: do not disassemble it internally. 

 
 
 
 

Summary of Contents for Tebas-Economic EFka300 pH/Chlor

Page 1: ...1 Tebas Economic EFka300 pH Redox EN INSTALLATION AND MAINTENANCE INSTRUCTIONS...

Page 2: ...has to be handled by qualified personnel only Always use original spare parts for maintenance Failure to follow instructions can cause damage to the equipment and in extreme cases to people The manuf...

Page 3: ...2 PRIMING 23 ELECTRICAL CONNECTIONS 23 Level Control 23 Flow Control 23 Internal Connections for technical personnel only 23 START UP 24 VISUALIZATIONS 24 OPERATION OF THE ELECTRONIC UNIT 25 Standard...

Page 4: ...in the Technical specifications section The unit must be installed on a vertical wall and securely clamped Choose a location that allows easy calibration operations use and maintenance Place the tanks...

Page 5: ...polyester front panel Installation wall installation with supplied screws and stoppers Protection Rate IP65 Dimensions 380 x 350 x 175 mm Fixing Template 356 x 250 mm Weight approx 5 kg Dimensions FUN...

Page 6: ...o the Configuration Calibration and Manual Mode menus confirms parameter modifications Key Scrolls the available menus options in calibration and configuration modes decreases the displayed value in m...

Page 7: ...es The foot filter must be located at a minimum distance of 5 cm from the tank bottom If a dense product is dosed it is recommended to remove the small inside filter from the foot valve in order to fa...

Page 8: ...ors while inputs for level sensors one for each pump and flow sensor are available on special connectors that allow an extremely fast and easy connection even for unskilled personnel Note the pH and r...

Page 9: ...ngly with the configured working mode VISUALIZATIONS During normal operations the display shows the two measured values on the top line while the bottom row displays the status of the two pumps In mod...

Page 10: ...d related explanations see the List of Configuration Parameters section Standard Configuration The standard configuration mode allows the customer to set a series of parameters related to the normal f...

Page 11: ...ot protected by password highlighted in bold in the table above PARAMETER 01 FUNCTIONING TYPE OF THE PUMP 1 This parameter allows to set the functioning type of pump 1 typically used for the pH contro...

Page 12: ...ALARM OF PUMP 2 See parameter P11 but referred to pump 2 PARAMETER 13 START UP DELAY This parameter allows to set a start up delay which is a time of waiting before starting measurements to allow the...

Page 13: ...pressing CAL 5 The system automatically recognizes and displays the buffer value 7 01 pH 6 If necessary use the keys to adjust the calibration value 7 Press CAL to confirm the calibration or ESC to qu...

Page 14: ...s ESC at any time to exit the manual mode Warning In manual mode only one pump at a time can be activated CONTROL EXAMPLES Typical application in swimming pool control acidification when pH exceeds th...

Page 15: ...stem is unplugged Dosing Pumps For a perfect seal after about 800 hours of work it is recommended to tighten the bolts of the pump by applying a torque of 4 Nm Weekly operations Check the level of the...

Page 16: ...8019 2231 SDE Transparent methacrylate down flow probe holder with standard connections for 8x12 tubes and sampling needle 8061 0252 Flow control kit for SDE electrode holder 9700 9203 EFK1 SGV Compl...

Reviews: