background image

31 

 

 

 

 

 

pH and Redox Electrodes 

Typically,  it  is  recommended  to  clean  the  electrodes  when  the  response  is  slow  or  measurements  are  not  reliable,  and 
when  they  have  been  used  for  a  long  time,  especially  in  aggressive  solutions,  pollutants,  very  acidic  or  very  alkaline 
environments. 

 

We provide a kit of solutions for the cleaning and storage of pH and redox electrodes.  
The kit includes three solutions: 

-

 

Solution A: dip the electrode in this solution for cleaning it 

-

 

Solution B: use this solution to rinse the electrode, before and after cleaning  

-

 

Solution  C:  storage  solution  to  be  used  for  filling  the  electrode  protective  cap  when  the  electrode  is  not  used 
(wintering, closure of the plant)   

 

 

ACCESSORIES AND SPARE PARTS   

Item 

Description 

Code 

pH Electrode 

Combined pH electrode with short plastic body, black head, 65 cm cable 
and BNC connector 

8009.2231 

RX Electrode 

Combined redox electrode with platinum sensor, short plastic body, 
black head, 65 cm cable and BNC connector 

8019.2231 

SDE 

Transparent methacrylate, down-flow probe-holder with standard 
connections for 8x12 tubes and sampling needle 

8061.0252 

 

Flow control kit for SDE electrode-holder 

9700.9203 

EFK1-SGV 

Complete PP pump head with Pyrex ball valves and FPM seals, for 
pumps 

9700.2101/SGV 

EFK2-SGV 

Kit of suction / head valves with PP body, Pyrex ball and FPM seals, for 
EFka pumps  

9700.2000/SGV 

EFK3-SGV 

Kit of suction / head / purge valves and O-ring for pump head. PP valves 
with Pyrex ball, FPM seals and O-ring 

9700.2001/SGV 

EFK4 

Maintenance kit including flange, PTFE diaphragm for pumps EF-
C11/C12, and FPM O-ring for pump head 

9700.2021 

EFK5 

Kit purge with PP valve and FPM seals 

9700.2026 

EFK6-SGV 

Standard accessory kit for pumps with FPM seals, including: foot filter 
and injection valve with PP body and Pyrex ball, 4x6 PVC Crystal tube 
(2+2 m), 4x6 in PE tube (2 m) 

9700.2010/SGV 

SLP2 

Level sensor with 2 m cable and connector  

9700.9002 

pH4-S 

pH 4 buffer solution, 90 ml bottle 

8009.0095 

pH7-S 

pH 7 buffer solution, 90 ml bottle 

8009.0096 

RX220-S 

Redox calibration solution (220 mV), 90 ml bottle 

8019.0091 

KRE 

Cleaning and storage kit for pH and redox electrodes 

8009.9902 

 

 

Summary of Contents for Tebas-Economic EFka300 pH/Chlor

Page 1: ...1 Tebas Economic EFka300 pH Redox EN INSTALLATION AND MAINTENANCE INSTRUCTIONS...

Page 2: ...has to be handled by qualified personnel only Always use original spare parts for maintenance Failure to follow instructions can cause damage to the equipment and in extreme cases to people The manuf...

Page 3: ...2 PRIMING 23 ELECTRICAL CONNECTIONS 23 Level Control 23 Flow Control 23 Internal Connections for technical personnel only 23 START UP 24 VISUALIZATIONS 24 OPERATION OF THE ELECTRONIC UNIT 25 Standard...

Page 4: ...in the Technical specifications section The unit must be installed on a vertical wall and securely clamped Choose a location that allows easy calibration operations use and maintenance Place the tanks...

Page 5: ...polyester front panel Installation wall installation with supplied screws and stoppers Protection Rate IP65 Dimensions 380 x 350 x 175 mm Fixing Template 356 x 250 mm Weight approx 5 kg Dimensions FUN...

Page 6: ...o the Configuration Calibration and Manual Mode menus confirms parameter modifications Key Scrolls the available menus options in calibration and configuration modes decreases the displayed value in m...

Page 7: ...es The foot filter must be located at a minimum distance of 5 cm from the tank bottom If a dense product is dosed it is recommended to remove the small inside filter from the foot valve in order to fa...

Page 8: ...ors while inputs for level sensors one for each pump and flow sensor are available on special connectors that allow an extremely fast and easy connection even for unskilled personnel Note the pH and r...

Page 9: ...ngly with the configured working mode VISUALIZATIONS During normal operations the display shows the two measured values on the top line while the bottom row displays the status of the two pumps In mod...

Page 10: ...d related explanations see the List of Configuration Parameters section Standard Configuration The standard configuration mode allows the customer to set a series of parameters related to the normal f...

Page 11: ...ot protected by password highlighted in bold in the table above PARAMETER 01 FUNCTIONING TYPE OF THE PUMP 1 This parameter allows to set the functioning type of pump 1 typically used for the pH contro...

Page 12: ...ALARM OF PUMP 2 See parameter P11 but referred to pump 2 PARAMETER 13 START UP DELAY This parameter allows to set a start up delay which is a time of waiting before starting measurements to allow the...

Page 13: ...pressing CAL 5 The system automatically recognizes and displays the buffer value 7 01 pH 6 If necessary use the keys to adjust the calibration value 7 Press CAL to confirm the calibration or ESC to qu...

Page 14: ...s ESC at any time to exit the manual mode Warning In manual mode only one pump at a time can be activated CONTROL EXAMPLES Typical application in swimming pool control acidification when pH exceeds th...

Page 15: ...stem is unplugged Dosing Pumps For a perfect seal after about 800 hours of work it is recommended to tighten the bolts of the pump by applying a torque of 4 Nm Weekly operations Check the level of the...

Page 16: ...8019 2231 SDE Transparent methacrylate down flow probe holder with standard connections for 8x12 tubes and sampling needle 8061 0252 Flow control kit for SDE electrode holder 9700 9203 EFK1 SGV Compl...

Reviews: