BO.sensor
Manual
19
/
39
v.1.7
© 2014 basalte
Parameter
Description
Use hardware buttons for KNX
When enabled, pressing the hardware buttons will send AUDIO
commands over KNX bus.
Use hardware buttons for
Beolink output
When enabled, pressing the hardware buttons will send native
B&O command via Beolink connector.
Audio source number when
PLAY
When the PLAY button on the IR sensor is pressed, following
source will be selected.
Options:
RADIO
AMEM
CD
SERVER
DOCK
Preset number when PLAY
When the PLAY button is pressed, following PRESET number will
be send on the selected source PRESET object.
Settings:
0-24
Timer timeout (min)
This parameter defines the duration of the timer function in
minutes.
Settings:
0-255