![background image](http://html1.mh-extra.com/html/bartscher/mc6040-5/mc6040-5_original-instruction-manual_4090883027.webp)
Installation Instructions
117900
25 / 86
EN
CAUTION!
Choking hazard!
Prevent children from accessing packaging materials, for instance: plastic
bags and EPS elements.
• Check if the appliance is undamaged.
• Before positioning the appliance, check the dimensions and exact positions of
the electric, water, and extraction connections.
• If the appliance is covered with a protective film, remove it. Remove the film
slowly, so no glue residues are left. Remove any glue residues with the use of a
suitable solvent.
• Be careful not to damage the rating plate and warning labels affixed to the
appliance.
• Remove all accessories, information materials, and plastic bags from the
appliance.
• Check if ventilation openings and fume extractor are not covered nor obstructed
in any way.
• Place the appliance in a way making the connections easily accessible, so that
they may be quickly disconnected if such a need arises.
•
Never place the appliance directly next to walls, low walls, division walls kitchen
furniture, or other surfaces made of flammable materials. Unconditionally
observe fire-fighting regulations in force.
• Walls and objects in the vicinity of the appliance must be made of non-
combustible materials (e.g. ceramic tiles, steel pallets) or be lined with non-
combustible thermal insulation material.
• When it is not possible to maintain the recommended clearance, employ
appropriate protective measures (e.g. a film made of a heat-resistant material)
that will ensure keeping the wall temperature within the safe range (up to 60°C).
• Position the appliance vertically — to this end, the height of adjustable feet is set
with a spirit level.
ATTENTION!
Differences in height or tilting may negatively influence the appliance's
functionality.
• Minimum clearances must be maintained from walls and combustible objects, as
shown in the following figure.