- 33 -
6.3 Safety instructions for maintenance
o
Check the mains connection cable for damage from time to time. Never operate the
device when the cable is damaged. A damaged cable must immediately be replaced
by customer service or a qualified electrician to avoid dangers.
o
In case of damage or malfunction, please contact your stockist or our customer
service centre. Pay attention to the troubleshooting tips in pt. 7.
o
Only a qualified technician and using original spare parts and accessories should
carry out repairs and maintenance of the device. Do not attempt to repair the
device yourself.
7. Possible Malfunctions
Error
Message
Cause
Solution
E01
•
Short-lasting power lower
tension (
<
160V).
•
Remove the unit from the socket
(remove the plug!). Re-connect the
unit after several minutes.
E02
•
Short-lasting power surge
tension (
>
270V).
•
Remove the unit from the socket
(remove the plug!). Re-connect the
unit after several minutes.
E03
•
The device becomes too
hot (e.g. due to blocked
ventilation slots).
•
Parts are damaged (e.g.
transistor).
•
Clear/unblock ventilation slots. Let the
device cool off for a few minutes; the
device is ready for operation
afterwards. Contact the retailer in case
the error message remains indicated
in the display after the device has
cooled off.
•
Contact retailer.
E05
•
Overheating-protection
on the power mode was
activated (
>
150 °C). The
device switched off.
•
Remove the cookware from the hob.
Let the device cool off for a few
minutes. The device is ready for
operation afterwards.
E06
•
Temperature sensor
defective or short circuit.
•
Contact retailer.
Summary of Contents for IK 30