- 58 -
•
The electric socket should be equipped with the 16A breaker. Connect directly to
the wall socket. You must not use any multiple socket or multi-socket adaptors.
•
The device is delivered with the certified power cord and plug. Do not tamper with or
modify them.
Potential difference connection
•
Installation for connection of device of different potentials using the clip
indicated as
. The clip is located at the rear of the device.
•
The clip is used to connect the potential difference wire (yellow-green) of a diameter
from 4 to 10 mm
2
.
•
The device should be connected to the potential difference circuit of the efficiency
according to the recommendations included in the current legal regulations.
5.1.5 Water connection
•
Ensure that the device is located near water connections.
•
If a new installation is to be put in, flush it out with water to remove all dirt and
impurities before connecting the device so as to protect the magnetic valves.
•
Connect the pressurised water hose (included) using the 90° connection bevel to
the connector (3/4“) of the device. Location of the connector: at the rear, at the
right side under the device. Connect the other end of the pressurised water hose
to the cold water network with the stopcock.
CAUTION!
Hydraulic pressure cannot exceed a maximum of 3 bars.
Use a reducing valve for higher pressures.
•
To ensure the device functions properly and prevent the formation of deposits in the
water boiling compartment, the water hardness can measure not more than 7° dH .
CAUTION!
If water hardness is above 7 °dH, it is necessary t o install a water softening
mechanism.