15
ENGLISH
GB
9.3.
Replacement of igniting flame burner nozzle (service technician)
Follow the instructions below.
Close the gas cut-off valve.
Open the cover (
A
)
The ignition flame is assigned to the burner.
Loosen the nut (B).
Remove the nozzle
C
and replace it with a
nozzle intended for the used gas (see
attached tables).
Tighten the nut and restore the initial settings.
Close the cover.
10. APPLIANCE DISPOSAL
The appliance is marked in conformity
with the European Directive 2002/96/EG
WASTE ELECTRICAL AND ELECTRONIC
EQUIPMENT (WEEE).
By disposing the appliance in
accordance with the regulations the user
contributes towards prevention of adverse
effects on environment and health.
The
symbol on the product or attached
manual indicates that the product cannot be
considered as ordinary household waste and
should be transferred to a special collection point
for electrical and electronic appliances for
recycling.
Local waste management regulations should be
observed.
Further information on procedure, reusing and
recycling of the product is available in local
offices, waste management unit or with the
product sales agent.
A
B
C