Unpack the appliance as soon as possible to
check if the appliance is not damaged.
Do not use a sharp object to cut the carton box. It
may damage the stainless steel inside the box.
Remove the carton packaging from bottom to top.
When unpacked check if the appliance is
according to the order.
In case of any difference inform the sales agent
immediately.
Do not store the packaging
materials (nylon bags, polystyrene foam,
clips ...) in the reach of children!
Remove the protective PVC layer from the out
and inner surfaces. If possible, do not use any
metal tools.
8.2.
Installation (service technician)
All the stages of the installation must be carefully
planned.
The location should be equipped with all supply
connections and production waste outlet. The
location should also be properly lit and comply
with all hygiene and sanitary requirements
according to the binding regulations.
The appliance should be installed with the
minimum 5 cm clearance from the wall, if the
wall is not resistant to the minimum temperature
of 150 °C.
Locate the appliance in the horizontal position by
adjusting the single feet.
To ensure the correct operation of
the appliance, the appliance must be
installed and operated in the thoroughly
ventilated room only.
Internal installation of the gas supply and the
rooms in which the appliance is housed, must
comply with the local regulations applicable in the
country in which the appliance is used (Regulation
of 12 June 96 and UNI-CIG 87/23).
In order to ensure the proper gas burning in the
burners the required volume of air, i.e. approx.
2 cubic meters per hour for every kW of installed
power, must be supplied.
8.3.
Water connection (service technician)
The installation is performed by connecting the
connection pipe of the appliance to the water
network pipe. Install the cut-off valve (A) on the
connection to stop the water supply when
required. Install appropriate filters after that valve.
Connect potable water to the
appliance.
Limit values for the potable
water specified by the European Union are
listed in the table.
Description
Value
Pressure
150-300 kPA
1.5-3 bar
pH
6.5-8
Hardness
8-15°F
(80-150 ppm CaCO3)
Minerals
<1500 mg/l
Iron
< 0.2 mg/l
Manganese
<0.05 mg/l
Chlorine
<0.25 mg/l
Sulphur
<0.25 mg/l
ID 12
ID 06